Chapter 4 Standard Mode
4-13 NWA-033628-001 Rev.1.0
[Implement] Category
STEP2: Set items (1) to (4).
Along with the station and trunk route, you can set two patterns of access number.
STEP3: Click the [OK] button.
You are directed back to the [Quick Setup] screen. Checked mark appears to the right of but-
ton [4].
The numbering plan has now been configured.
No. Item Description
(1) Station Station Number
(Digits) field
Select a station number length.
1 to 8 digits (default: 4 digits)
(2) Access Code field Select a station number access code.
Up to 4 digits [0 to 9, *, #, blank field] (default: upper...4,
lower... 3)
(3) Trunk
Route
Trunk Route
(Route Number)
field
Select a trunk route number.
00 to 63 (default: upper...01, lower...02)
(4) Access Code field Select a trunk route access code.
Up to 4 digits [0 to 9, *, #,blank field] (default: blank field
= not set)
[OK] button
(1)
(2)
(1)
(2)
(3)
(4)
(3)
(4)

Table of Contents