Chapter 4 Standard Mode
4-16 NWA-033628-001 Rev.1.0
[Implement] Category
No. Item Description
(1) [Fill In] button Click to apply the settings entered on the first line to other
lines as well.
STN No. field
Station numbers are assigned in sequential numbering
from the first line.
* Numbers containing * or # cannot be set.
Automatic entry stops before first digit of a station number
change (example: 3999).
TN No. , RFC (Day)/ (Night), SFC (A)/ (B)/ (C) fields:
The same values as the first line are set.
Port No. and Name Display fields:
Out of the scope of continuous entry.
(2) [Clear] button Click to initialize the settings to their defaults.
(3) System Data
Setup Area
Port No. field Displays the Port number (unit number + slot number + line
number) of the line that houses a Single Line Telephone or
Digital Multiline Terminal.
STN No. field Enter a station number associated with the port number.
Up to 8 digits [0 to 9, *, #, blank field] (default: A station
number is entered automatically when it is entered accord-
ing to the numbering plan setting.)
TN No. field Select a station tenant number.
00 to 63 (default: 01)
RSC (Day)/
(Night) field
Select the trunk restriction class of each station:
Unrestricted (RCA)/Non-Restricted 1 (RCB)/Non-
Restricted 2 (RCC)/Semi-Restricted 1 (RCD)/Semi-
Restricted 2 (RCE)/Restricted 1 (RCF)/Restricted 2
(RCG)/Fully-Restricted (RCH) (default: Unrestricted
(RCA))
SFC (A)/(B)/
(C) field
Select the service restriction class A, B or C of each station.
00 to 15 (default: 15)
Name Dis-
play field
Enter a station name displayed on LCD of the Digital Multi-
line Terminal. (default: blank)
Up to 16 characters