30
PROGRAMMING
NESS D8 (V4.7) CONTROL PANEL – INSTALLER MANUAL
50Hz MAINS FREQUENCY
Selects either 50Hz or 60Hz mains power frequency operation. Leave the factory
default for use in Australia and New Zealand. Users in North America should
select 60Hz mains frequency.
Required for the accurate timing of dialler test reports (if programmed). It has no
effect on local or other dialler operations.
PROGRAMMING SE QUENCE:
P64E 5E toggles the option ON and OFF
P64E 5E OFF: 60Hz mains frequency
P64E 5E ON: 50Hz mains frequency
P64E 5E
PROGRAM MODE LEVEL:
Installer, Remote by PC
FACTORY DEFAULT:
ON: 50Hz mains frequency
NOTES:
DOUBLE KEY KEYPAD PANIC
This option allows the Keypad Panic alarm to be triggered by pressing both
Panic buttons together.
NOTE: [User Code] always triggers Keypad Panic
PROGRAMMING SE QUENCE:
P64E 6E toggles the option ON and OFF
P64E 6E OFF: No double key Keypad Panic
P64E 6E ON: Double key Keypad Panic enabled
P64E 6E
PROGRAM MODE LEVEL:
Installer, Remote by PC
FACTORY DEFAULT:
ON: Double key Keypad Panic enabled
NOTES:
RELATED OPTIONS:
P62E 4E Shortcut Keypad Panic
The Ness LCD keypad has two buttons
labelled
KEYPAD FIRE ALARM
This option enables the Keypad Fire Alarm. Pressing and then triggers the
siren using the “Fire Alarm” siren sound.
If P75E 4E is enabled, the fi re alarm is reported by dialler to the central station.
PROGRAMMING SE QUENCE:
P64E 7E toggles the option ON and OFF
P64E 7E OFF: No Keypad Fire Alarm
P64E 7E ON: Keypad Fire Alarm enabled
P64E 7E
PROGRAM MODE LEVEL:
Installer, Remote by PC
FACTORY DEFAULT:
OFF: No Keypad Fire Alarm
NOTES:
RELATED OPTIONS:
P68E 6E Fire Siren sound
P75E 4E Report Fire Alarms
KEYPAD MEDICAL ALARM
This option enables the Keypad Medical Alarm. Pressing and then
activates the dialler and reports a Medical Alarm.
If P75E 2E must be enabled for the Medical alarm to be reported.
PROGRAMMING SE QUENCE:
P64E 8E toggles the option ON and OFF
P64E 8E OFF: No Keypad Medical Alarm
P64E 8E ON: Keypad Medical Alarm enabled
P64E 8E
PROGRAM MODE LEVEL:
Installer, Remote by PC
FACTORY DEFAULT:
OFF: No Keypad Medical Alarm
NOTES:
RELATED OPTIONS:
P75E 2E Report Medical Alarms