NESS D8 (V4.7) CONTROL PANEL – INSTALLER MANUAL
D8 VERSION 4.7 (Aug 2003)
BUSY dial tone detection removed.
Allow remote operation with P86E 1E (Dialler Disable ON).
Up/download can still take place if Client Account Number (P72E,
P73E) is left at default value of 0000.
DTMF tone transmission OFF time reduced to match other NESS
diallers.
Improved central station tone detection.
Pulse output time reduced to 2.5 seconds for AUX1, AUX2 when
triggered by Radio Panic and Aux key.
Line Fail to Aux2 delay time reduced to 1 minute.
V4.6 (Released in D16 only Jan 2003)
New Feature - Temporary Day Zones. Enable or Disable Day
Zones from operating mode. Page 19.
Dialler Client Codes for transmission to a central station can be
entered in HEX. Page 39.
Mains fail alarm can be disabled Page 37.
Test report clock can be programmed to use the internal oscillator
for timing. Page 49.
Zones can be selected not to fl ash the Memory icon. Page 52.
RK4 Radio Key AUX button can be mapped to the D8 Aux2
output. Page 37.
CHANGES TO EXISTING PROGRAM OPTIONS
P63E 6E. Day Mode to Strobe becomes Day Mode to AUX2 if
P64E 2E is on.
P64E 2E, Brief Day Alarm is now defaulted OFF.
NEW PROGRAM OPTIONS
P69E 6E Disable mains fail alarm.
P69E 7E RK4 Radio Key AUX button toggles Aux2 output.
P69E 8E RK4 Radio Key AUX button pulses Aux2 output.
P89E 7E Internal clock timing.
P94E Select zones for no memory warning.
NEW FUNCTIONS.
P+E enters Temporary Day Zone Selection Mode. Accessed from
normal operating mode.
[Zone No.]+E selects Temporary Day Zones when in Temporary
Day Zone Selection Mode.
0+E Enables or disables Day Mode. Accessed from normal
operating mode.
E Exits Temporary Day Zone Selection Mode.
D8 VERSION 4.5 (July 2002)
MONITOR ARMING BY RADIO KEY. Pressing the ON button twice
can now be used to enter MONITOR mode. This addition was done
to allow MONITOR mode arming using a RADIO keypad.
TEST CALL TIMING. When sending Test Calls, the time between
dialling attempts is increased to 60 minutes for the 2nd round
of dialling.
Arming from MONITOR Mode. Arm Only codes can arm the panel
directly from Monitor Mode. (Normal user codes can arm only
from the disarmed state.)
STROBE TIMEOUT. Strobe output will time out af ter 72 hour s. This
stops continuous strobe operation when the alarmed premises
are vacant for long periods.
S/W VERSION. The software version of the panel is displayed in
Program mode by entering P99999999E (eight 9’s).
D8 VERSION 4 (Nov 2001)
RADIO
RADIO SUPERVISION. Radio supervision can be used with NESS
radio detectors that transmit periodic supervision signals.
Options added to either Toggle or Pulse Aux1 with the Radio
Panic key.
Option to have quieter siren chirps when arming/disarming with
key switch or radio keys.
ARMING
ARM ONLY CODES. User codes and radio Keys can now be
made to ARM ONLY.
Option for siren warning burst when arming with radio key and
a zone is unsealed.
Warning beeps timing extended by changing to Entry Delay 2
timer.
Monitor mode outputs are now selectable for both the 2 second
monitor mode and full monitor mode.
The outputs for Area 1 and Area 2 can now be made to pulse on
for 2 seconds. This makes them useful as Smoke Detector Reset
outputs by adding an external relay.
DIALLER
Aux 2 output option for telephone line fail.
Dialler sends a CANCEL report if there has been an alarm in full
monitor mode.
Dialler Listen-In has been added via the Siren output.
The Miscellaneous Alarm reporting options have been increased
to include reports such as Mains Fail, Battery Fail, radio tamper
reports and others now selectable).
Mains and Battery fail reports can be sent if required when using
the Audible format.
Closing reports can be delayed until end of exit time.
Manual and Auto Exclude reports can be disabled.
UP/DOWNLOAD
CallBack in Normal Mode and User Program mode is now optional
to allow up/download without having a fi xed callback telephone
number.
The Up/Download Software is completely new and compatible
with Windows 9x/2K/XP.
HARDWARE
An option to select 3k3 EOL resistors for Zones. Default is 2k2.
A Tamper lead assembly is provided to connect internal tamper
switch to the Tamp header.
MISCELLANEOUS
Only include mains fail in alarm memory when the previous event
is not mains fail.
Fire Siren sound can be selected for 24hr zones. Handy for
Smoke Detectors.
Day mode does not latch zone alarms. The warnings are either
for 2secs or while the Day zone is unsealed.
Zone Exclude with User Code Entry only accepts zones (1-8) that
are in the AREAS that the User Code can arm.
In User Program Mode a Siren Test can be started by entering
77777777E (8 sevens) and Dialler Test Report can be initiated by
entering 66666666 ( 8 sixes).
Quiet siren sound option in Monitor mode, instead of the full
volume siren sound.
NESS D8 REVISION HISTORY