41
PROGRAMMING
NESS D8 (V4.7) CONTROL PANEL – INSTALLER MANUAL
REPORT MISCELLANEOUS ALARMS
REPORT MISCELLANEOUS RESTORALS
These options select which Miscellaneous alarms will trigger the dialler to send
Alarm reports and Restoral reports to the Central Station.
Alarms (if enabled) are sent on activation. Restorals (if enabled) are sent on
Opening. Mains Fail and Low Battery Restorals are sent when the power has been
restored.
PROGRAMMING SEQUENCE:
PxxE 1E–8E
toggles the option ON and OFF
P75E, P92E
REPORT MISCELLANEOUS ALARMS
PROGRAM MODE LEVEL:
Installer, Remote by PC
FACTORY DEFAULT:
see table
NOTES:
• 0E will turn all selections OFF
MEMORY E will turn all selections ON
P77E, P93E
REPORT MISCELLANEOUS RESTORALS
PROGRAM MODE LEVEL:
Installer, Remote by PC
FACTORY DEFAULT:
see table
NOTES:
• Mains Fail and Low Battery Restorals are
sent when the power has been restored
• 0E will turn all selections OFF
MEMORY E will turn all selections ON
1E 2E 3E 4E 5E 6E 7E 8E
ON = Factory default setting.
Restoral immediately
Restoral after siren time
Restoral on Disarm & seal
Restoral on Disarm always
.
.
.
.
OPTION No DESCRIPTION
P82E Zone Restoral reporting options
ON
RESTORAL REPORTING OPTIONS
This option selects when the dialler sends zone Restoral reports. Only one of the
following options may be selected.
Restoral reporting options also apply to 24hr zones.
PROGRAMMING SE QUENCE:
P82E 1E–4E toggles the option ON and OFF
P82E 1E: Send Restoral immediately
P82E 2E: Send Restoral after siren time
P82E 3E: Send Restoral on Disarm & seal
P82E 4E: Send Restoral on Disarm always
P82E 1E–4E
PROGRAM MODE LEVEL:
Installer, Remote by PC
FACTORY DEFAULT:
4E, ON: Always send Restoral on Disarm
NOTES:
• RELATED OPTIONS:
P76E Report zone restorals
ON = Factory default setting.
OPTION No DESCRIPTION
P75E Report Misc. Alarms 1~8 ON ON ON ON ON ON ON ON
ONONONONONONONONONONONONONONONON
P77E
Report Misc. Restorals 1~8
P92E
Report Misc. Alarms 9~14
P93E
Report Misc. Restorals 9~14
1E Duress
2E Medical
3E K/P & K/S Panic
4E Fire
5E Panel Tamper
6E External Tamper
7E Keypad Tamper
8E Exit Install mode
1E Radio Tamper
2E Radio Panic
3E Radio Battery
4E Supervision Fail
5E Panel Battery
6E Mains Fail
7E
8E
1. Duress
2. Medical
3. Keypad & K/Switch Panic
4. Fire
5. Panel Tamper
6. External Tamper
7. Keypad Tamper
8. Exit Install Mode
9. Radio Tamper
10. Radio Panic (by User)
11. Radio Low Battery (by Device)
12. Supervision Fail
13. Panel Low Battery
14. Mains Fail
1E
2E
3E
4E
5E
6E
7E
8E
1E
2E
3E
4E
5E
6E
ALARM
ALARM
P75E
P92E
RESTORAL
RESTORAL
P77E
P93E
MISCELLANEOUS ALARMS: