NESS RADIO
NESS D8 (V4.7) CONTROL PANEL – INSTALLER MANUAL
RADIO DEVICES – OPERATION
ALARM: Any Ness Radio Device can operate on any zone 1–8 as programmed by
P01E-P08E. The hardwired zones 1–8 continue to operate in parallel.
Radio Keys can also operate on radio zones 1–8 for special purposes, but they should
normally be used as Radio Codes.
KEYSWITCH INPUT: A Radio Device programmed to Zone 8 will still work as an alarm even
if the Zone 8 input operation has been changed to Keyswitch operation. The P60E 2E and
3E options only affect the Zone 8 terminal inputs.
VIBRATION: Radio device zone signals IGNORE the P30E–P38E vibration sensor settings.
TAMPER REPORT: Radio Device Tamper operation depends on the Armed State of the
control panel.
RADIO TAMPER: causes the keypad to continuously beep and also to fl ash the RADIO,
TAMPER and the ZONE (identifying the detector) lights. Pressing any key on the keypad or
sending a TAMPER RESTORE will clear this warning.
LOW BATTERY REPORT: A low battery gives 10 beeps and fl ashes the RADIO & the
BATTERY light. The ZONE light identifying the radio device is also ON. The fl ashing lights
stop when any key on the keypad is pressed or a detector code with no low battery is
received. Low Battery generates HISTORY and DIALLER reports ONCE only (until the low
battery is fi xed and a restore report is received).
SUPERVISION: If a zone has the P65E option ON and a radio code has been programmed
for that zone, then the supervision is active. This means that the radio detector does not
need to have its SUPER enabled (via header link) for the SUPERVISED timeout to occur.
(Useful as an inactivity alarm). A zone supervision failure always fl ashes the identifying ZONE
light and the RADIO light.
RADIO SUPERVISION
The purpose of Radio Supervision is to verify the correct operation of Ness Radio
PIRs. The Supervision signal from the Radio PIR tells the panel that the device has
not been removed from radio range and is in working order.
Non-SUPERVISION Radio PIRs can also be programmed and used with the D8
SUPERVISION TIMERS.
A non-SUPERVISION enabled Radio PIR will transmit signals to the D8 only when
it has detected an event. Obviously, there is no guaranteed signal period.
In either case, when the allowed time limit is exceeded then a WARNING is fi rst
given (if programmed by P66E 3E), and then after 1 minute, the programmed
RADIO SUPERVISION ALERTS are generated by the D8.
NOTE: Manually Excluding a Supervised Zone will also disable Radio Supervision
for that zone.
RK1 RADIO KEY
PENDANT
RKP
RADIO KEYPAD
100-665100-001
RK3 RADIO KEY
3 BUTTON
RK4 RADIO KEY
4 BUTTON
100-664 100-067
R12 RADIO PIR
R15 RADIO PIR
100-691/100-663
RR1/RR2 RADIO
REED SWITCH
RPB RADIO
EMERG BUTTON
100-662/100-527 100-283
RSM RADIO
SMOKE DETECTOR
100-203
SIGNAL
TYPE
NESS RADIO DEVICES
Radio Events Table
ALARM
ARM / DISARM
PANIC button PANIC button PANIC button
yes
yesyes
yes
PANIC button* [star buttons]
yes yes
yes
yes
yes yes yes yes
yes
yes yes yes
ON/OFF buttons ON/OFF buttons15 User IDs
yes yes yes
RESTORAL
LOW BATT
AUX
PANIC
TAMPER
SUPERVISION
O
FF
O
N
PA
N
I
C
RKP