29
PROGRAMMING
NESS D8 (V4.7) CONTROL PANEL – INSTALLER MANUAL
BRIEF MONITOR MODE ALARM
Alarms in Monitor Mode can either activate the programmed outputs for Siren
Time duration (P29E) or they can activate the outputs for 2 seconds only.
PROGRAMMING SE QUENCE:
P64E 1E toggles the option ON and OFF
P64E 1E OFF: Monitor Mode outputs have normal time as set by P29E
P64E 1E ON: Monitor Mode outputs are ON for 2 seconds only
P64E 1E
PROGRAM MODE LEVEL:
Installer, Remote by PC
FACTORY DEFAULT:
OFF: Brief Monitor Alarm disabled
NOTES:
• RELATED OPTIONS:
P51E Set Monitor zones
P63E 1E–4E Monitor Mode output mapping
P64E 2E
PROGRAM MODE LEVEL:
Installer, Remote by PC
FACTORY DEFAULT:
OFF: Brief Day Alarm disabled
NOTES:
• RELATED OPTIONS:
P53E Assign Day zones
P63E 5E–8E Day Mode output mapping
MONITOR ZONES ENTRY DELAY 2
Monitor zones can either have the delay types set by options P40E–P43E or they
can all be assigned to have Entry Delay 2. This allows all Monitor zones to be
programmed with the same entry delay time.
PROGRAMMING SE QUENCE:
P64E 3E toggles the option ON and OFF
P64E 3E OFF: Monitor zones behave as programmed by P40E–P43E
P64E 3E ON: Monitor zones all have Entry Delay 2
P64E 3E
PROGRAM MODE LEVEL:
Installer, Remote by PC
FACTORY DEFAULT:
ON: Monitor zones all have Entry Delay 2
NOTES:
• RELATED OPTIONS:
P27E Entry Delay Time 2
P51E Assign Monitor zones
P63E 1E–4E Monitor Mode output mapping
ARM/DISARM CHIRPS
If this option is selected the Siren output will "Chirp" when the panel is Armed and
Disarmed with the Keyswitch input or Radio Keys. This option applies to siren
chirps - the strobe output always fl ashes when arming/disarming by keyswitch or
radio key.
The panel will make 1 Chirp on Arming, and 3 Chirps on Disarming.
PROGRAMMING SE QUENCE:
P64E 4E toggles the option ON and OFF
P64E 4E OFF: No Arm/Disarm siren chirps
P64E 4E ON: Siren & Strobe outputs will chirp on arm/disarm
P64E 4E
PROGRAM MODE LEVEL:
Installer, Remote by PC
FACTORY DEFAULT:
OFF: No siren chirps
NOTES:
• RELATED OPTIONS:
P68E 8E Quiet Chirps
1E 2E 3E 4E 5E 6E 7E 8E
ON = Factory default setting.
2 second Monitor Alarm
2 second Day Alarm
Monitor zones Entry2
Radio Key chirp & flash
50Hz mains frequency
Double key Keypad Panic
Keypad Fire Alarm
Keypad Medical Alarm
OPTION No DESCRIPTION
P64E Miscellaneous options ON ONON ON
BRIEF DAY ALARM
Alarms in Day Mode will activate the programmed outputs while the zone is
unsealed or they can activate the outputs for 2 seconds only.
This option also enables the TEMPORARY DAY ZONE feature. See page 19.
PROGRAMMING SE QUENCE:
P64E 2E toggles the option ON and OFF
P64E 2E OFF: Brief Day Alarm disabled. Day alarm outputs are ON while the zone is unsealed
P64E 2E ON: Brief Day Alarm Enabled. Day alarm outputs are ON for 2 seconds only