PROGRAMMING
NESS D8 (V4.7) CONTROL PANEL – INSTALLER MANUAL
1E 2E 3E 4E 5E 6E 7E 8E
ON = Factory default setting.
Split dial Phone Nos.
Check for dial tone
.
4 dialling attempts
.
.
.
.
OPTION No DESCRIPTION
P87E Miscellaneous Dialling Options
ON ON
SPLIT DIAL PRIMARY/SECONDARY PHONE NUMBERS
This option selects the order in which Telephone numbers 1 & 2 are dialled.
PROGRAMMING SE QUENCE:
P87E 1E toggles the option ON and OFF
P87E 1E OFF: Alternate Dial
Dial Telephone No.1 on the fi rst attempt. If no answer, dial Telephone No.2.
Continue alternating until successful.
P87E 1E ON: Split Dial
Dial Telephone No.1 for half of the call attempts. If unsuccessful, dial Telephone No.2 for the
last half of call attempts.
P87E 1E
PROGRAM MODE LEVEL:
Installer, Remote by PC
FACTORY DEFAULT:
OFF: Alternate Dial
NOTES:
RELATED OPTIONS:
P87E 4E Number of Dialling attempts
CHECK FOR DIAL TONE
The dialler normally dials only if a dial tone is detected. The dialler can be forced
to dial without a dial tone. Allows use on PABXs with non-standard dial tones.
PROGRAMMING SE QUENCE:
P87E 2E toggles the option ON and OFF
P87E 2E OFF: Dial without dial tone
P87E 2E ON: Dial only with dial tone
P87E 2E
PROGRAM MODE LEVEL:
Installer, Remote by PC
FACTORY DEFAULT:
ON: Dial only with dial tone
NOTES:
NUMBER OF DIALLING ATTEMPTS
Sets the number of dialling attempts when sending reports.
OFF: sets a maximum 10 dial attempts before a 5 minute sleep and 10 more re-
tries if unsuccessful.
ON: allows a maximum of 4 dial attempts before a 5 minute sleep and 4 more
retries if unsuccessful.
If all attempts fail the dialler waits for the next trigger event. The previously
unsuccessful report will be included in the new message.
When sending Test Calls, the time between dialling attempts increases to 60
minutes for the second round of dialling. If a Test Call is unsuccessful after the fi rst
round of calls are made, another call is made after 5 minutes. If this call fails then
subsequent calls are made every hour (up to the maximum number of calls).
PROGRAMMING SE QUENCE:
P87E 4E toggles the option ON and OFF
P87E 4E OFF: Maximum 10 dialling attempts
P87E 4E ON: Maximum 4 dialling attempts
P87E 4E
PROGRAM MODE LEVEL:
Installer, Remote by PC
FACTORY DEFAULT:
ON: 4 dialling attempts
NOTES:
Sets the total number of dialling attempts.
E.g. If 4 dialling attempts is selected, this
means 2 attempts per telephone number.
RELATED OPTIONS:
P87E 1E Alternate dialling