36
PROGRAMMING
NESS D8 (V4.7) CONTROL PANEL – INSTALLER MANUAL
1E 2E 3E 4E 5E 6E 7E 8E
ON = Factory default setting.
ARM1 pulse output
ARM2 pulse output
Quiet Monitor siren
6 beeps on Arming
Radio Key Monitor Arming
Disable Mains Fail alarm
Aux2 toggle
Aux2 pulse
OPTION No DESCRIPTION
P69E Miscellaneous options 2
ARM1 PULSE OUTPUT
This option selects the ARM1 output to pulse on for 2 seconds whenever arming
or disarming of Area1. (The ARM1 output normally toggles when arming/
disarming).
Note also that when Arming with the P60E 8E option selected that the pulse will
occur at the end of Exit Time.
PROGRAMMING SE QUENCE:
P69E 1E toggles the option ON and OFF
P69E 1E OFF: ARM1 output toggles
P69E 1E ON: ARM1 output pulses
P69E 1E
PROGRAM MODE LEVEL:
Installer, Remote by PC
FACTORY DEFAULT:
OFF: ARM1 output toggles
NOTES:
• This is useful as a Smoke Detector reset
output with an optional external relay.
RELATED OPTIONS:
P60E 8E Delay ARM1/ARM2 outputs
ARM2 PULSE OUTPUT
This option selects the ARM2 output to pulse on for 2 seconds whenever Arming
or Disarming of Area2.
(The ARM2 output normally toggles when arming/disarming).
Note also that when arming with the P60E 8E option selected that the pulse will
occur at the end of Exit Time.
PROGRAMMING SE QUENCE:
P69E 2E toggles the option ON and OFF
P69E 2E OFF: ARM2 output toggles
P69E 2E ON: ARM2 output pulses
P69E 2E
PROGRAM MODE LEVEL:
Installer, Remote by PC
FACTORY DEFAULT:
OFF: ARM2 output toggles
NOTES:
• This is useful as a Smoke Detector reset
output with an optional external relay.
RELATED OPTIONS:
P60E 8E Delay ARM1/ARM2 outputs
QUIET MONITOR SIREN
This option selects the ‘Quiet Siren’ sound in Monitor Mode. The Quiet Siren
sound is a continuous “beep beep beep” sound rather than the normal siren
sound.
PROGRAMMING SE QUENCE:
P69E 3E toggles the option ON and OFF
P69E 3E OFF: Normal siren sound in Monitor Mode
P69E 3E ON: Quiet Siren sound in Monitor Mode
P69E 3E
PROGRAM MODE LEVEL:
Installer, Remote by PC
FACTORY DEFAULT:
OFF: Normal siren sound in Monitor Mode
NOTES:
• This does not affect the RESET output
6 BEEPS ON ARMING
Normally the keypad/s onboard SONALERT gives 3 beeps when the D16 is
Armed. Turning this option ON will give 6 keypad beeps when Arming.
PROGRAMMING SE QUENCE:
P69E 4E toggles the option ON and OFF
P69E 4E OFF: Keypad gives 3 beeps on Arming
P69E 4E ON: Keypad gives 6 beeps on Arming
P69E 4E
PROGRAM MODE LEVEL:
Installer, Remote by PC
FACTORY DEFAULT:
OFF: Keypad gives 3 beeps on Arming
NOTES:
• The keypad beeps on Arm/Disarm when
Arming/Disarming by keypad, keyswitch
or by Radio Key

Table of Contents