63
NESS D8 (V4.7) CONTROL PANEL – INSTALLER MANUAL
P68E P86E
P88E
P89E
P90E
P92E
P87E
P69E
P82E
1E 1E
1E
1E
1E
1E
1E
1E
1E
2E 2E
2E
2E
2E
2E
2E
2E
2E
3E 3E
3E
3E
3E
3E
3E
3E
3E
4E 4E
4E
4E
4E
4E
4E
4E
4E
5E 5E
5E
5E
5E
5E
5E
6E 6E
6E
6E
6E
6E
6E
7E
7E
7E
7E
7E
7E
8E
8E
8E
8E
8E
8E
[D16 option only] Disable Dialler
AREA 1 OPEN/CLOSE REPORTS
Enable Test Calls
(Also see P83E, P84E)
Enable Remote Access
Report Radio Tamper
Split Dial Primary/Sec. numbers
Arm1 Output Pulses
Send Restoral Immediately
3K3 End Of Line Resistors CONTACT ID FORMAT
Area 2 Open/Close Reports
Mains Report Delay
Enable Direct Connect
Report radio Panic by User ID
Check For Dial Tone
Arm2 Output Pulses
Send Restoral after Siren Time
Radio Key Toggles Aux1 Audible DTMF format
Siren Chirp on Kiss-Off
Listen-in to Dialler
Enable Remote Arming
Report Radio Battery by Device
[not used]
AUDIBLE PULSE FORMAT
Flash Strobe on Kiss-Off
Swinger Shutdown
Enable Remote Disarming
Report Radio Supervision Fail
Reduced Dialling Attempts
Contact ID & Audible DTMF
Forced Opening Report
Telephone Line Fault Monitor
Enable Remote AUX Control
Report Panel Low Battery
Contact ID & Audible Pulse
Delayed Closing Reports
Line Fault Alarms to Aux2
Enable Remote Status Report
Report Mains Fail
Manual Exclude Reports
Internal Timing
Enable Remote Event Report
[not used]
[not used]
Auto Exclude Reports
[not used]
Enable Callback Mode
Quiet Monitor Siren
Send Restoral on Disarm & seal
Radio Key Pulses Aux1
6 Beeps On Arming
Send Restoral on Disarm always
Radio Arming Unseal Warning
Radio Key Arming Monitor Mode
24hr Zones Fire Siren Sound
Disable Mains Fail Alarm
RK4 Radio Key AUX button to Aux1
RK4 AUX button Toggles Aux2
Quiet Chirps on Radio Arm/Disarm
RK4 AUX button Pulses Aux2
OFF
OFF
OFF
OFF
ON
ON
ON
ON
OFF
OFF
OFF
OFF
OFF
ON
ON
ON
ON
OFF
OFF
OFF OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
ON
ON
ON
ON
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
ON
OFF
OFF
OFF
OFF
OFF
ON
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
ON
ON
ON
ON
OFF
34, 35
36, 37
43, 44
46, 47
48, 49
50, 51
41
45
41
P70E
P71E
P72E
P73E
TELEPHONE NUMBER 1 (Primary)
Telephone Number 2
ACCOUNT NUMBER 1
Account Number 2
0000
0000
P95E
P96E
P97E
P98E
Clear Radio Devices
Clear Memory
(Except Radio Devices, User Codes
or Radio Keys)
CLEAR PANEL OPTIONS
Clear User Codes & Radio Keys
53
P85E 1E
2E
3E
Auto Dialling, Pulse or DTMF
Pulse Dialling always
DTMF Dialling always
OFF
ON
OFF
P75E
Report MISC. alarms 1–8
Report MISC. alarms 9–14
P74E
P76E
P79E
P83E
P91E
P93E
P99E
P94E
P77E
P80E
P84E
P78E
P81E
1E
2E
3E
4E
5E
6E
7E
8E
Report Duress alarms
REPORT ZONE ALARMS 1–8
Report Zone Restorals 1–8
Account Number 2 zones
Test Call Interval
Required Rings To Answer
Report Misc. Restorals 9–14
Set Installer Code
No Memory Warning zones
Report Misc Restorals 1–8
Telephone No. 3 for Test Calls
Time Before Next Test Call
Also see P89E 1E, Enable Test Calls
Report Multiple Zone alarms
Telephone No. 4 for Callback
Report Panel Tamper alarms
Report Medical alarms
Report external Tamper alarms
Report Keypad & Keyswitch Panic
Report Keypad Tamper alarms
Report Fire alarms
Report Exit From Installer Mode
OFF
OFF
OFF
all zones
all zones
84=168hrs
1
all ON
000000
all ON
6=12hrs
41
40
38
40
40
42
42
52
53
52
41
39
40
39
DESCRIPTION DEFAULT PAGEOPTION DESCRIPTION DEFAULT PAGEOPTION
D8 V4.7 OPTIONS SUMMARY - PAGE 2 OF 2

Table of Contents

Other manuals for Ness D8

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Ness D8 and is the answer not in the manual?

Ness D8 Specifications

General IconGeneral
BrandNess
ModelD8
CategoryControl Panel
LanguageEnglish

Related product manuals