DAY ZONES
Day Zones operate when the panel is fully disarmed, i.e. when Area 1, Area 2 and
Home Mode are all off. When alarmed, these zones will activate their assigned outputs
instantly.
The outputs mapped to the Day Zone will turn on while the zone is unsealed. Turn
P64E 2E on, to limit Day Zone alarms to 2 seconds.
The Temporary Day Zones feature allows day mode to be easily enabled/disabled and
day zones added/removed by the user from any keypad.
PROGRAMMING SEQUENCE:
P53E [Zone No]E toggles the options ON and OFF
[Zone No] OFF: The zone is not a Day zone
[Zone No] ON: The zone is a Day zone
P53E
PROGRAM MODE LEVEL
Installer, Remote by PC
FACTORY DEFAULT
all OFF.
RELATED OPTIONS
P63E 5E-8E Day zone output mapping.
P64E 2E Brief Day Mode alarm.
IDEAS FOR DAY ZONE USE
• Instant alert for a delivery door.
• Doorway alert for a shop.
• Pool gate opened warning.
24hr ZONES
24hr Zones operate at all times regardless of the mode of panel operation, i.e. Armed,
Disarmed or Home Mode. When alarmed, these zones will activate assigned outputs
immediately. To reset those alarms a valid user code must be entered.
Selecting a zone as 24hr will override any other zone type setting such as Instant,
Delayed or Handover. 24hr zones are independent of Area operation. All other zone
types must be assigned to at least one Area to become active.
PROGRAMMING SEQUENCE:
P52E [Zone No]E toggles the options ON and OFF
[Zone No] OFF: The zone is not a 24hr zone
[Zone No] ON: The zone is a 24hr zone
P52E
PROGRAM MODE LEVEL
Installer, Remote by PC.
FACTORY DEFAULT
All OFF.
NOTES
• When a zone is selected as 24hr it is
automatically removed from both Areas.
When a 24hr zone is assigned to an
Area (P45E or P46E) it is no longer a 24hr
zone.
HOME MODE ZONES
Home Mode zones allow you to Arm selected zones while others are ignored. Typically
used for perimeter zones such as windows and doors while you are at home.
For example: upstairs zones are Disarmed while downstairs zones are Armed in Home
mode.
PROGRAMMING SEQUENCE:
P51E [Zone No]E toggles the options ON and OFF
P51E [Zone No]E OFF: The zone is not a Home zone
P51E [Zone No]E ON: The zone is a Home zone
P51E
PROGRAM MODE LEVEL
Installer, Remote by PC.
FACTORY DEFAULT
all OFF.
NOTES
Home zones can be Instant, Delayed or
Handover depending on attributes set by
options P40E–P42E.
RELATED OPTIONS
P63E 1E-4E Home Mode output mapping.
P64E 1E Brief Home Mode alarm.
P69E 3E Quiet Home Mode siren.
P69E 5E Home Mode by Radio Key ON/
OFF buttons.
P69E 7E Home Mode chirps.
P69E 8E Home Mode arm by Radio Key
AUX button.
NOTE: Zones selected to Report Zone Alarms (P74E) will by default report alarms in
Home Mode, (if the dialler is enabled).
The Brief Home Alarm option P64E 1E, when enabled, prevents Home Mode alarms
from reporting.
See page 18 for information on TEMPORARY DAY ZONES.
See page 18 for Home Mode operation.
19
Ness eCO8x CONtrOl PaNel – INstallatION MaNual
P R O G R A M M I N G