OPERATION SUMMARY
OPERATION by KEYPAD by RADIO KEY
to ARM
The panel must initially be disarmed.
Press +
(If the Arming Shortcut is enabled, P62E 5E)
Press the ON button once.
or press + [user COde] +
or press [user COde] +
(If Code Only Arming has been enabled for that
user code. Extra Option 4E)
to DISARM
To disarm and/or reset alarms.
Press [user COde] +
Press the
OFF button
once.*
to arm HOME MODE
Area1 must initially be disarmed.
Home Mode can be used if the panel
is fully disarmed or if only Area2 is
armed, see pages 18-19 for more
information.
Press +
(If the Home Mode Shortcut is enabled, P62E 3E)
Press either the
OFF button or the
ON button twice
within 4 seconds.
(P69E 5E must
be on).
or press + [user COde] +
PANIC alarm
Press
Fire & Medical keys together
(If KeyPad PaNIC is enabled, P64E 6E)
Press and hold
the PANIC button
for at least 4 sec.
KEYPAD DURESS
Keypad Duress allows the user to send
a silent duress report while disarming, (if
the system is being monitored by a central
station).
Press [5, 6, 8 Or 9]+[user COde] +
Add one these digits in front of a user code when disarming.
This sequence will disarm the panel and send a Duress report by dialler to the central
station. (Report Keypad Duress must be enabled, P75E 1E)
EXCLUDE ZONES
EXCLUDE + E can only be used when the
panel is disarmed.
EXCLUDE + CODE + E
can be used
anytime.
Press + (If the Exclude Shortcut is enabled, P62E 2E)
then [ZONe NO.]+ [ZONe NO.]+ (Enter the zone number/s to be excluded.)
then press to exit Exclude mode
The Exclude light flashes constantly while zones are excluded. Excluded zones are
automatically Included next time the panel is disarmed.
* If a user code is assigned to a radio key and has Extra Option 4E enabled, (Code Only arming), then pressing OFF toggles the
panel arm/disarm state.
TEMPORARY DAY ZONE (TDZ) operation
While remaining in normal operating mode, the user can add and remove Temporary Day Zones and enable/disable day zone
operation.
The panel must initially be disarmed.
P64E 2E must be on to enable the
use of Temporary Day Zones.
See page 18 for more information on
Temporary Day Zones.
Press + To enter TDZ Selection Mode.
then press [ZONe NO.] + To select one or more zone to be Temporary Day Zones.
then press To save changes and exit TDZ Selection Mode.
Press + To enable/disable TDZ operation.
The HOME light flashes continuously when Day Mode is enabled
9
Ness eCO8x CONtrOl PaNel – INstallatION MaNual

Other manuals for Ness ECO8x

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Ness ECO8x and is the answer not in the manual?

Ness ECO8x Specifications

Power IconPower
plug pack voltage240 V AC
plug pack output voltage17 V AC
plug pack output current1.4 A
power supply voltage13.8 V DC
power supply current800 mA
Battery IconBattery
battery voltage12 V
battery capacity7.0 Ah
battery charging current350 mA
Inputs and Outputs IconInputs and Outputs
zone inputs8
end of line resistor2200 Ohms
maximum keypads3
Weight and Dimensions IconWeight and Dimensions
box width235 mm
box height300 mm
box depth90 mm