DISABLE DIALLER
This option disables the dialler even if telephone numbers and other dialler options are
programmed.
Up/download or remote telephone access remain enabled.
PROGRAMMING SEQUENCE:
P86E 1E turns the option ON
ON: Dialler disabled
P86E 1E
PROGRAM MODE LEVEL
Installer, Remote by PC.
FACTORY DEFAULT
OFF. (Dialler is enabled)
NOTES
• This option is useful for temporary
disabling of the dialler without affecting
other dialler options.
CONTACT ID FORMAT
This option enables the reporting of alarms to a Central station via telephone numbers
1 & 2 using Contact ID format.
PROGRAMMING SEQUENCE:
P86E 2E turns the option ON
ON: Contact ID format enabled
P86E 2E
PROGRAM MODE LEVEL
Installer, Remote by PC.
FACTORY DEFAULT
ON.
AUDIBLE FORMAT
For audible monitoring to any telephone or mobile phone.
The audible message consists of the warning words ALARM, ALARM, ALARM followed
by the alarm message sent as a series of beeps:
The message is repeated for 4 times or until acknowledged by the receiving telephone.
PROGRAMMING SEQUENCE:
P86E 4E turns the option ON
ON: Audible PULSE format enabled
P86E 4E
PROGRAM MODE LEVEL
Installer, Remote by PC.
FACTORY DEFAULT
OFF.
NOTES
See page 53 for full details.
Disable Dialler
Contact ID Format
Audible PULSE format
Option No. Description
1E 2E 3E 4E 5E 6E 7E 8E
P86E
REPORTING FORMATS
ON
39
Ness eCO8x CONtrOl PaNel – INstallatION MaNual
P R O G R A M M I N G