CENTRAL STATION MONITORING
The Ness ECO8x control panel has an on-board digital dialler which can send detailed
alarm messages to a central monitoring station.
The digital messages can include information about the zone/s which caused the
alarm, tamper alarms, low battery or mains failure reports, and it can also (by user
number) identify the users who arm and disarm the system.
Central station monitoring is highly recommended and is the most effective method of
monitoring your alarm system.
Installers are welcome to contact Ness for further information about monitoring.
MONITORED
PREMISES
CENTRAL STATION MONITORING
TELEPHONE LINE
MONITORING
STATION
REPORT NAME SSSS Q XYZ GG CCC SUFFIX
Zone 1– Zone 8 Alarm ssss 18 q 130 aa 001–008 k
Duress
ssss 18 1 121 01 030 k
Keyswitch Panic ssss 18 1 120 01 031 k
Keypad Panic ssss 18 1 120 01 032 k
Radio Key Panic ssss 18 1 120 01 1dd k
Medical Alarm ssss 18 1 100 01 033 k
Fire ssss 18 1 110 01 034 k
Exit Install mode
ssss 18 1 306 01 035 k
Internal Tamper
ssss 18 q 137 01 041 k
Keypad Tamper ssss 18 q 137 01 042 k
Radio Sensor Tamper ssss 18 q 383 01 2zz k
Radio Sensor Low Battery ssss 18 q 384 01 3zz k
Mains Fail ssss 18 q 301 01 050 k
Panel Battery Fail ssss 18 q 309 01 051 k
Open
ssss 18 1 402 aa 0dd k
Force Open (Cancel)
ssss 18 1 406 aa 0dd k
Close ssss 18 3 402 aa 0dd k
Test Report ssss 18 1 602 01 063 k
Zone 1-8 Manual Exclude ssss 18 q 573 aa 001-008 k
Zone 1-8 Auto Exclude ssss 18 q 380 aa 001-008 k
CONTACT ID REPORTS TA-
The panel reports alarms to the Central
Station using Contact ID dialler format.
The message format is fixed as shown
in the Contact ID Codes Table.
ThE MESSAGE TAkES ThE FORM OF:
SSSS Account Number
Q Event qualifier
1=New Event or Open
3=Restore or Close
XYZ Alarm type
GG Group or Area designation
CCC Alarm number
dd=User ID (1 to 15)
zz = Zone ID (1 to 8)
aa = 01 Area 1
aa = 02 Area 2
aa = 01 Home Mode area
aa = 00 24 Hr Area
K = Checksum (0 to 0f hex)
Keyswitch arming is identified as User 16. Shortcut arming is identified as User 17.