50Hz MAINS FREQUENCY
Selects either 50Hz or 60Hz mains power frequency operation. The factory default of
50Hz is for use in Australia and New Zealand. Users in North America should select
60Hz mains frequency.
Required for the accurate timing of dialler test reports (if programmed). It has no effect
on other dialler operations.
PROGRAMMING SEQUENCE:
P64E 5E toggles the option ON and OFF
OFF: 60Hz mains frequency
ON: 50Hz mains frequency
P64E 5E
PROGRAM MODE LEVEL
Installer, Remote by PC.
FACTORY DEFAULT
ON.
ENABLE KEYPAD PANIC
This option enables the operation of Keypad Panic. Pressing both the FIRE & MEDICAL
keys together activates a Panic alarm.
PROGRAMMING SEQUENCE:
P64E 6E toggles the option ON and OFF
OFF: Keypad Panic disabled
ON: Keypad Panic enabled
P64E 6E
PROGRAM MODE LEVEL
Installer, Remote by PC.
FACTORY DEFAULT
ON.
RELATED OPTIONS
P61E 5E-8E Keypad Panic Alarm output
mapping.
KEYPAD FIRE ALARM
This option enables the operation of the keypad Fire Alarm. A Fire alarm is activated by
pressing the FIRE key followed by E.
The SIREN output changes to the FIRE sound.
If P75E 4E is enabled, the fire alarm is reported by dialler to the central station.
PROGRAMMING SEQUENCE:
P64E 7E toggles the option ON and OFF
OFF: No Keypad Fire Alarm
ON: Keypad Fire Alarm enabled
P64E 7E
PROGRAM MODE LEVEL
Installer, Remote by PC.
FACTORY DEFAULT
OFF.
RELATED OPTIONS
P75E 4E Report Fire Alarms.
KEYPAD MEDICAL ALARM
This option enables the operation of the keypad Medical Alarm. A Medical alarm is
activated by pressing the MEDICAL key followed by E.
The keypad medical alarm can send a Medical Alarm report by dialler.
The option P75E 2E must be enabled for the Medical alarm to be reported.
PROGRAMMING SEQUENCE:
P64E 8E toggles the option ON and OFF
OFF: No Keypad Medical Alarm
ON: Keypad Medical Alarm enabled
P64E 8E
PROGRAM MODE LEVEL
Installer, Remote by PC.
FACTORY DEFAULT
OFF.
RELATED OPTIONS
P75E 2E Report Medical Alarms.
28
Ness eCO8x CONtrOl PaNel – INstallatION MaNual