SEND DIALLER TEST REPORT
Send a Dialler Test Report to the telephone numer programmed at P70E.
This test operates only in User program mode.
P66666666E (eight 6’s) Triggers dialler and sends test report to Central Station
SIREN TEST
Turn the Siren, Reset and Strobe Outputs On. Pressing P E will stop the Siren Test (and
also exits Program Mode).
This test operates in User and Installer program mode.
P77777777E (eight 7’s) Triggers Siren, Reset, Strobe
PANEL RESET
This function resets the microprocessor. The effect is the same as powering down and
powering up again. Panel Reset operates in User and Installer program mode.
P88888888E (eight 8’s) Panel Reset
PANEL MODEL & SOFTWARE VERSION
This function displays the panel software version and the model number.
Displayed in decimal format by the zone LEDs.
Example, version 1.0 ECO8x is displayed by flashing 1 0 followed by 0 2. (The model
number for the ECO8x is 02.)
This test operates in User and Installer program mode.
P99999999E (eight 9’s) Displays software version
SPECIAL INSTALLER FUNCTIONS