ECO8x OPTIONS SUMMARY Page 1 of 2
OPTION
DESCRIPTION
DEFAULT PAGE
P26E
ENTRY DELAY Time
20 sec
14
P28E
EXIT DELAY Time
60 sec
P29E
SIREN RESET Time
5 min
P30E
Normal Zone Sensitivity
all zones
15
P31E-36E
Vibration Sensitivity, High-Low
none
P37E
Long Response Zones - 1 second
none
P38E
Long Response Zones - 3 seconds
none
P39E
Double Trigger zones
none
16
P40E
Instant zones
zones 3+
P41E
ENTRY DELAY
zones
Zone 1
P42E
HANDOVER
zones
Zone 2
17
P44E
Lockout zones (RESET output)
All zones
P45E
AREA 1 zones
All zones
P46E
AREA 2 zones
none
P51E
HOME MODE
zones
none
19
* See page 18 for information on Area operation, Home mode & Temporary
Day Zones
P52E
24hr zones
none
19
P53E
Day Mode zones
none
P54E
RESET output zones
All zones
20
P55E
STROBE zones
All zones
P56E
Keypad Sonalert zones
All zones
P57E
SIREN zones
All zones
21
P59E
Aux2 zones
none
P60E
1E Entry Beeps
ON
22, 23
3E Keyswitch Arm/Disarm
OFF
4E Tamper Siren lockout
ON
6E Auto Exclude zones
ON
7E Auto keypad display off
OFF
P61E
1E Tamper to RESET output
ON
24
2E Tamper to STROBE output
ON
3E Tamper to Keypad Sonalert
ON
4E Tamper to SIREN output
ON
5E Keypad Panic to RESET output
ON
6E Keypad Panic to STROBE output
ON
7E Keypad Panic to Sonalert
ON
8E Keypad Panic to SIREN output
ON
P62E
1E Shortcut Memory display
ON
25
2E Shortcut Zone Exclude
ON
3E
Shortcut Home Mode
ON
4E
Shortcut SMOKE RESET
OFF
5E
Shortcut Area1 Arming
ON
6E Shortcut Area 2 Arming
OFF
7E
Siren Burst on Auto Exclude
ON
8E Exit Time x10
OFF
u
u
u
Options marked "u" can be programmed in User Program Mode
All options can be programmed in Installer Program Mode
u
u
PROGRAMMING USER CODES
PIN programming and EXTRA OPTIONS for each user code.
USER CODE TABLE
EXTRA OPTIONS
EXCLUDE+E toggles EXTRA OPTIONS
mode. (Installer Program mode only)
PAGE
12 Pge 49
USER
CODE
OPTION
NO.
KEYPAD
PIN
1E
AREA
1
Code
2E
AREA
2
Code
3E
ARM
ONLY
4E
"CODE
ONLY"
ARM
5E
RADIO
Code
1 (Master) P11E 123
ON
ON
2 P12E
ON
3 P13E
ON
4 P14E
ON
5 P15E
ON
6 P16E
ON
7 P17E
ON
8 P18E
ON
9 P19E
ON
10 P20E
ON
11 P21E
ON
12 P22E
ON
13 P23E
ON
14 P24E
ON
15 P25E
ON
u
PROGRAMMING RADIO DEVICES
Radio PIRs, Radio Reed Switches, Radio Smoke Detectors.
OPTION DESCRIPTION
PAGE
P01E Program radio devices on zone 1
48
P02E Program radio devices on zone 2
P03E Program radio devices on zone 3
P04E Program radio devices on zone 4
P05E Program radio devices on zone 5
P06E Program radio devices on zone 6
P07E Program radio devices on zone 7
P08E Program radio devices on zone 8
PROGRAMMING RADIO KEYS
To program Radio Keys to the panel, assign the required user code/s
to be Radio Codes (Extra Options Mode, enable 5E).
Example, to program a Radio key to User Code 15:
Press P25E EXCLUDE E 5E EXCLUDE E 1E then press the OFF
button on the radio key.
For full instructions see page 49.
54