ECO8x OPTIONS SUMMARY Page 2 of 2
OPTION
DESCRIPTION
DEFAULT PAGE
P63E
1E
Home Mode alarms to RESET output
ON
26
2E
Home Mode alarms to STROBE
ON
3E
Home Mode alarms to SONALERT
OFF
4E
Home Mode alarms to SIREN
OFF
5E Day Mode to RESET output
ON
6E Day Mode to STROBE
ON
7E Day Mode to keypad SONALERT
OFF
8E Day Mode to SIREN
OFF
P64E
1E
Brief Home Mode Alarm
OFF
27, 28
2E Brief Day Alarm
OFF
3E Enable Keypad Chime
OFF
4E Radio Key SIREN CHIRPS
OFF
5E 50Hz Mains Frequency
ON
6E
Enable Keypad Panic
ON
7E Keypad Fire Alarm
OFF
8E Keypad Medical Alarm
OFF
P65E
1E Aux1 = Smoke Detector Power
OFF
29
2E Aux1 = Area1 armed output
OFF
3E Aux1 = Toggle on Radio AUX button
OFF
4E Aux1 = Pulse on Radio AUX button
ON
P66E
1E Aux2 = Zone alarm output
OFF
30
2E Aux2 = Area2 armed output
ON
3E Aux2 = Toggle on Radio PANIC button
OFF
4E Aux2 = Pulse on R adio PANIC button
OFF
5E Aux2 = Line Fail output
OFF
6E Aux2 = Fail To Communicate output
OFF
P68E
2E 3K3 Zone Resistors
OFF
31
8E Quiet chirps on radio Arm/Disarm
OFF
P69E
1E ARM1 output pulses
OFF
32, 33
2E ARM2 output pulses
OFF
3E
Quiet Home Mode Siren
OFF
5E
Home Mode by Radio Key ON/OFF buttons
OFF
6E Disable Mains Fail Alarm
OFF
7E
Home Mode chirps (Radio Key arm)
OFF
8E
Home Mode by Radio Key AUX button
OFF
P70E
TELEPHONE N
o.1 Primary
NONE
34
P71E
Telephone No.2 Secondary
NONE
P72E ACCOUNT No. 1
0000
35
P74E
REPORT ZONE ALARMS
All zones
36
P75E
Report
Misc
Alarms
1-8
1E Report DURESS alarms
OFF
37
2E Report MEDICAL alarms
OFF
3E Report keypad & Keyswitch PANIC
ON
4E Report FIRE alarms
OFF
5E Report PANEL TAMPER alarms
ON
6E Report EXTERNAL TAMPER alarms
ON
7E Report KEYPAD TAMPER alarms
ON
8E Report EXIT FROM INSTALLER mode
OFF
P76E
Report Zone Restorals
All on
36
P77E
Report Misc. Restorals
All on
37
P78E
Report Multiple Zone alarms
NONE
36
P81E
Telephone No. Callback
NONE
34
OPTION
DESCRIPTION
DEFAULT PAGE
P82E
1E
Send RESTORAL report immediately
OFF
37
2E
Send RESTORAL after siren time
OFF
3E
Send RESTORAL after Disarm & seal
OFF
4E
Send RESTORAL after Disarm always
ON
P83E
TEST CALL
Interval
84 (168hrs)
38
P84E
Time before FIRST TEST CALL
6 (12hrs)
P85E
1E Auto Dialling, Pulse & DTMF
OFF
38
2E
Pulse Dialling (Decadic) always
OFF
3E DTMF Dialling always
ON
P86E
1E Disable Dialler
OFF
39
2E CONTACT ID FORMAT
ON
4E
Audible Format
OFF
P87E
1E Split dial Primary/Secondary numbers
OFF
40
2E Check for Dial Tone
ON
4E 4 Dialling attempts
ON
P88E
1E Send AREA 1 OPEN/CLOSE REPORTS
OFF
41
2E Send AREA 2 Open/Close reports
OFF
5E Forced Opening report
ON
7E Manual Exclude Reports
ON
8E Auto Exclude Reports
ON
P89E
1E ENABLE TEST CALLS
ON
42, 43
2E Mains Report Delay (1 hour)
ON
3E Listen-In to Dialler
OFF
4E Swinger shutdown
ON
5E Line Fault Monitor
OFF
7E Use Internal Timing
OFF
P90E
1E Enable Remote Access
OFF
44
7E Enable Remote Event Report
OFF
8E Enable Callback Mode
OFF
P91E
Required rings to answer
1
44
P92E
Report
Misc
Alarms
9-14
1E Report RADIO TAMPER
ON
37
2E Report RADIO PANIC by User ID
ON
3E
Report RADIO LOW BATTERY by device
OFF
4E Report ZONE SUPERVISION FAIL
OFF
5E Report PANEL LOW BATTERY
ON
6E Report MAINS FAIL
ON
P93E
Report Misc. Restorals 9-14
All on
P95E
CLEAR RADIO DEVICES
45
P96E
CLEAR MEMORY
P97E
CLEAR PANEL OPTIONS
(restore Factory Defaults)
P98E
CLEAR User codes and Radio Keys
P99E
Program the INSTALLER CODE
000000
45
P130E
Real Time Clock set MINUTES
00
50
P131E
Real Time Clock set HOURS
00
P132E
Real Time Clock set DAY
01
P133E
Real Time Clock set MONTH
01
P134E
Real Time Clock set YEAR
06
P135E
Real Time Clock set DAY OF WEEK
1
55
Ness eCO8x CONtrOl PaNel – INstallatION MaNual