CLEAR MEMORY
Enter P96E when in Installer Program mode to clear all events in the Alarm memory
display.
PROGRAMMING SEQUENCE:
P96E Clears Alarm Memory display
P96E
PROGRAM MODE LEVEL
Installer, Remote by PC.
FACTORY DEFAULT
[not applicable]
CLEAR PANEL OPTIONS
This option restores panel program options to their factory default values.
Defaults all options except User Codes, Radio Codes & Radio Devices.
PROGRAMMING SEQUENCE:
P97E Restores Factory Defaults
P97E
PROGRAM MODE LEVEL
Installer, Remote by PC.
FACTORY DEFAULT
[not applicable]
NOTES
CLEAR USER CODES
This option clears all User Codes, (includes all Keypad Codes and Radio Keys) and
restores User Code 1 to the factory setting of 123.
P11E – P25E are defaulted (User Codes 1–15)
PROGRAMMING SEQUENCE:
P98E Clears User Codes
P98E
PROGRAM MODE LEVEL
Installer, Remote by PC.
FACTORY DEFAULT
User Code 1: 123
All other codes: [blank]
NOTES
This option DOES NOT clear the Installer
Code.
CLEAR RADIO DEVICES
This option clears all Radio Devices assigned to zones 1–8.
(This option does not clear User Codes).
PROGRAMMING SEQUENCE:
P95E Clears Radio Device Codes
P95E
PROGRAM MODE LEVEL
Installer, Remote by PC.
FACTORY DEFAULT
[not applicable]
These options allow selective restoring
of various factory defaults. For example,
you can default (clear) all the User
Codes, without affecting any other
programmed options.
PROGRAM THE INSTALLER CODE
Programs the installer code. This code can be 3 to 6 digits long. Factory default
installer code is 000000.
PROGRAMMING SEQUENCE:
P99E [Enter new code]E [Enter new code again]E
(Unlike User Codes, the installer code is not displayed when programming)
P99E
PROGRAM MODE LEVEL
Installer, Remote by PC.
FACTORY DEFAULT
000000
For a complete list of factory default values, see the
Programming Options Summary on pages 54-55.
Option No. Description
P95E CLEAR RADIO DEVICES
P96E CLEAR MEMORY
P97E CLEAR PANEL OPTIONS (RESTORE FACTORY DEFAULTS)
P98E CLEAR USER CODES
P99E PROGRAM INSTALLER CODE