Tamper to RESET output
Tamper to STROBE output
Tamper to keypad SONALERT
Tamper to SIREN output
KP Panic to RESET output
KP Panic to STROBE output
KP Panic to keypad SONALERT
KP Panic to SIREN output
Option No. Description
1E 2E 3E 4E 5E 6E 7E 8E
P61E
TAMPER & PANIC ALARM MAPPING
ON ON ON ON ON ON ON ON
TAMPER ALARM / OUTPUT MAPPING
This option selects which outputs will trigger when a Tamper Alarm occurs.
PROGRAMMING SEQUENCE:
P61E 1E–4E toggles the options ON and OFF
1E ON: Tamper Alarm to Reset output
2E ON: Tamper Alarm to Strobe output
3E ON: Tamper Alarm to Keypad Sonalert output
4E ON: Tamper Alarm to Siren output
P61E 1E–4E
PROGRAM MODE LEVEL
Installer, Remote by PC.
FACTORY DEFAULT
1E–4E, ON.
NOTES
A Tamper Alarm is triggered by removing
the PROG/TAMP link on the main board.
KEYPAD PANIC ALARM / OUTPUT MAPPING
This option selects which outputs will trigger when a Keypad Panic alarm occurs.
PROGRAMMING SEQUENCE:
P61E 5E–8E toggles the options ON and OFF
5E ON: Keypad Panic Alarm to Reset output
6E ON: Keypad Panic Alarm to Strobe output
7E ON: Keypad Panic Alarm to Keypad Sonalert output
8E ON: Keypad Panic Alarm to Siren output
P61E 5E–8E
PROGRAM MODE LEVEL
Installer, Remote by PC.
FACTORY DEFAULT
5E–8E, ON.
NOTES
Press FIRE & MEDICAL keys together for
Keypad Panic.
RELATED OPTIONS
P64E 6E Enable Keypad Panic