REPORT MISCELLANEOUS ALARMS
REPORT MISCELLANEOUS RESTORALS
These options select which Miscellaneous alarms will trigger the dialler to send Alarm
reports and Restoral reports to the Central Station.
Alarms (if enabled) are sent on activation. Restorals (if enabled) are sent on Opening.
Mains Fail and Low Battery Restorals are sent when the power has been restored.
PROGRAMMING SEQUENCE:
PxxE
1E–8E toggles the option ON and OFF
P75E, P92E
REPORT MISCELLANEOUS
ALARMS
PROGRAM MODE LEVEL
Installer, Remote by PC.
FACTORY DEFAULT
see table
NOTES
• 0E will turn all selections OFF
MEMORY E will turn all selections ON
P77E, P93E
REPORT MISCELLANEOUS
RESTORALS
PROGRAM MODE LEVEL
Installer, Remote by PC.
FACTORY DEFAULT
see table
RESTORAL REPORTING OPTIONS
This option selects when the dialler sends zone Restoral reports. Only one of the
following options may be selected.
Restoral reporting options also apply to 24hr zones.
PROGRAMMING SEQUENCE:
P82E 1E–4E toggles the option ON and OFF
1E ON: Send Restoral immediately
2E ON: Send Restoral after siren time
3E ON: Send Restoral on Disarm & seal
4E ON: Send Restoral on Disarm always
P82E 1E–4E
PROGRAM MODE LEVEL
Installer, Remote by PC.
FACTORY DEFAULT
4E, ON.
RELATED OPTIONS
P76E Report zone restorals.
Send immediately
Send after siren time
Send after disarm & seal
Send after disarm always
Option No. Description
1E 2E 3E 4E 5E 6E 7E 8E
P82E
ZONE RESTORAL REPORTING OPTIONS
ON
ALARM RESTORAL
Option No.
DEFAULT
Option No.
DEFAULT
Duress
P75E 1E P77E 1E ON
Medical
P75E 2E P77E 2E ON
KP Panic & KS Panic
P75E 3E ON P77E 3E ON
Fire
P75E 4E P77E 4E ON
Panel tamper
P75E 5E ON P77E 5E ON
External tamper
P75E 6E ON P77E 6E ON
Keypad Tamper
P75E 7E ON P77E 7E ON
Exit Installer Mode
P75E 8E P77E 8E ON
Radio Tamper
P92E 1E ON P93E 1E ON
Radio Panic
P92E 2E ON P93E 2E ON
Radio Battery
P92E 3E P93E 3E ON
Supervision fail
P92E 4E P93E 4E ON
Panel battery
P92E 5E ON P93E 5E ON
Mains fail
P92E 6E ON P93E 6E ON
[not used]
P92E 7E P93E 7E ON
[not used]
P92E 8E P93E 8E ON