BRIEF HOME MODE ALARM
Alarms in Home Mode can either activate the programmed outputs for Siren Time
duration (P29E) or they can activate the outputs for 2 seconds only.
NOTE: If Brief Home alarm is enabled, then Home Mode alarms will not be reported by
dialler.
PROGRAMMING SEQUENCE:
P64E 1E toggles the option ON and OFF
OFF: Home Mode outputs have normal time as set by P29E
ON: Home Mode outputs are ON for 2 seconds only
P64E 1E
PROGRAM MODE LEVEL
Installer, Remote by PC.
FACTORY DEFAULT
OFF.
RELATED OPTIONS
P51E Set Home zones.
P63E 1E–4E Home Mode output
mapping
P64E 2E
PROGRAM MODE LEVEL
Installer, Remote by PC.
FACTORY DEFAULT
OFF.
RELATED OPTIONS
P53E Assign Day zones.
P63E 5E–8E Day Mode output
mapping.
RADIO KEY SIREN CHIRPS
If this option is selected the Siren output will "Chirp" when the panel is armed and
disarmed with the Keyswitch input or Radio Keys. This option applies to siren chirps,
the strobe output always flashes when arming/disarming by the above methods.
The siren output will make 1 Chirp on arming, and 3 Chirps on disarming.
Home Mode chirps are enabled separately, see P69E 7E.
PROGRAMMING SEQUENCE:
P64E 4E toggles the option ON and OFF
OFF: No Arm/Disarm siren chirps
ON: Siren & Strobe outputs will chirp on arm/disarm
P64E 4E
PROGRAM MODE LEVEL
Installer, Remote by PC.
FACTORY DEFAULT
OFF.
RELATED OPTIONS
P68E 8E Quiet Chirps.
P69E 5E Home Mode arming by Radio
Key ON/OFF buttons.
P69E 7E Home Mode by radio key
Chirps.
BRIEF DAY ALARM
Alarms in Day Mode will activate the programmed outputs while the zone is unsealed
or they can activate the outputs for 2 seconds only.
This option also enables the TEMPORARY DAY ZONE feature. See page 18.
PROGRAMMING SEQUENCE:
P64E 2E toggles the option ON and OFF
OFF: Brief Day Alarm disabled. Day alarm outputs are ON while the zone is unsealed
ON: Brief Day Alarm Enabled. Day alarm outputs are ON for 2 seconds only
Brief Home Mode alarm
Brief Day alarm
Enable keypad Chime
Radio Key chirp
50Hz mains frequency
Double key Keypad Panic
Keypad Fire Alarm
Keypad Medical Alarm
Option No. Description
1E 2E 3E 4E 5E 6E 7E 8E
P64E
MISC. OPTIONS
ON ON
P64E 3E
PROGRAM MODE LEVEL
Installer, Remote by PC.
FACTORY DEFAULT
OFF.
NOTES
Note that not all keypads have the
Chime sound.
RELATED OPTIONS
P64E 1E Brief Home Mode Alarm.
KEYPAD CHIME
This option enables the keypad Chime sound for Brief Home Mode Alarm (if P64E 1E is
enabled) and for Day Mode sounds. If this option is disabled the normal keypad beep
will sound.
PROGRAMMING SEQUENCE:
P64E 3E toggles the option ON and OFF
OFF: Keypad Chime disabled.
ON:
Keypad Chime enabled.
27
Ness eCO8x CONtrOl PaNel – INstallatION MaNual
P R O G R A M M I N G