5 Getting started
The E300 Elevator drive has a remote mount keypad (Local Remote Keypad). Each keypad has the same LCD text display.
Figure 5-1 Keypad buttons
5.1 Keypad set-up menu
To enter the keypad set-up menu press and hold the escape button from status mode. All the keypad parameters are saved to non-volatile
memory when exiting from the set-up menu. To exit from the set-up menu press the escape or or button.
Table 5-1 Keypad set-up parameters
It is not possible to access the keypad parameters via any communications channel.
Incorrect operation
Adjustment of drive parameters could result in a risk of damage to the product or present a safety hazard. Careful consideration to the
adjustment of drive parameters must be taken. The user should ensure they are familiar with parameter access, navigation and
parameter operation by reading this guide before adjustment to avoid the risk of damage to the product or a potential safety hazard.
WARNING
The keypad consists of a number of buttons, keys as detailed following which support navigation
and editing.
1. Escape button - Used to exit from parameter edit or view mode. In parameter edit mode, if
parameter values are edited and the exit button pressed, the parameter value will be restored
to the value it had on entry to edit mode.
2. Start reverse (Auxiliary) button - Not used.
3. Start forward button - Not used.
4. Navigation keys (x4) - Used to navigate through the menu and parameter structure and edit
parameter values.
5. Reset button - Used to reset the drive.
6. Enter / Mode button - Used to toggle between parameter edit and view mode.
Parameter Range Type
Keypad.00 Language RW
Keypad.01 Show units Off (0), On (1) RW
Keypad.02 Backlight level 0 to 100 % RW
Keypad.03 Keypad date (RTC Keypad) 01.01.10 to 31.12.99 RO
Keypad.04 Keypad time (RTC Keypad) 00:00:00 to 23:59:59 RO
Keypad.05 Show numerated text values Off (0), On (1) RW
Keypad.06 Software version 00.00.00.00 to 99.99.99.99 RO
Keypad.07 Language Version 00.00.00.00 to 99.99.99.99 RO