8.12 Menu M: Comms
Menu M Comms provides set-up parameters to allow the user to configure the serial communications interface fitted to the front of the Elevator drive
in Slot 4.
The Elevator drive offers a 2 wire EIA-485 interface via the option module fitted in Slot 4 which supports drive set-up, operation and monitoring carried
out with a PC or an Elevator controller where required. The EIA-485 user interface operates as a Modbus RTU slave with a user selectable extension
to allow for parameter numbers up to 255.
It should be noted that some non-recoverable drive faults, trips (Priority 1 or 2 trips) disable most of the functions within the drive, if one of these drive
faults, trips is active the drives serial communications will not function.
Parameter
Range Default
Type
Open-Loop RFC-A RFC-S Open-Loop RFC-A RFC-S
M01 Serial Address 1 to 247 1 RW Num US
M02 Serial Mode
8 2 NP (0), 8 1 NP (1), 8 1 EP (2), 8 1 OP (3),
8 2 NP M (4), 8 1 NP M (5), 8 1 EP M (6),
8 1 OP M (7), 7 2 NP (8), 7 1 NP (9),
7 1 EP (10), 7 1 OP (11), 7 2 NP M (12),
7 1 NP M (13), 7 1 EP M (14), 7 1 OP M (15)
8 2 NP (0) RW Txt US
M03 Serial Baud Rate
300 (0), 600 (1), 1200 (2), 2400 (3), 4800 (4),
9600 (5), 19200 (6), 38400 (7), 57600 (8),
76800 (9), 115200 (10)
19200 (6) RW Txt US
M04 Minimum Comms Transmit Delay 0 to 250 ms 2 ms RW Num US
M05 Silent Period 0 to 250 ms 0 ms RW Num US
M06 Reset Serial Communications Off (0) or On (1)
RW Bit ND NC
M07 Keypad Port Serial Address 1 to 16 1 RW Num US
RW Read / Write RO Read-only Bit Bit parameter Txt Text string Date Date parameter Time Time parameter
Chr
Character
parameter
Bin Binary parameter IP IP address Mac MAC address Ver Version number SMP
Slot, menu,
parameter
Num Number parameter DE Destination ND No default value RA Rating dependent NC Non-copyable PT Protected
FI Filtered US User save PS Power-down save