EasyManua.ls Logo

Nidec E300 Series - Menu E: Mechanical

Nidec E300 Series
314 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Safety
information
Product
information
Mechanical
installation
Electrical
installation
Getting
started
User Menu A Commissioning
Advanced
Parameters
Diagnostics Optimization CT MODBUS RTU Technical Data
Installation and System Design Guide 207
Issue Number: 1
8.4 Menu E: Mechanical
Menu E Mechanical allows the user to setup the mechanical data, scaling used for the Elevator system control
In addition to the standard Elevator system mechanical data Menu E Mechanical also allows the user to setup the external load cell compensation
and maximum speed, overspeed detection.
Elevator system mechanical data Elevator system maximum speed, overspeed detection
External Elevator system load cell compensation used during starting Inertia compensation set-up
Parameter
Range(Ú) Default(Ö)
Type
Open-Loop RFC-A RFC-S Open-Loop RFC-A RFC-S
E01 Nominal Elevator Speed 0 to 1000 mm/s
0 to 10000 mm/s
1000 mm/s RW Num US
E02 Sheave Diameter 1 to 32767 mm 400 mm 480 mm RW Num US
E03 Roping 1:1 (1), 2:1 (2), 3:1 (3), 4:1 (4) 1:1 (1) RW Txt US
E04 Gearbox Ratio Numerator 1 to 32767 31 1 RW Num US
E05 Gearbox Ratio Denominator 1 to 32767 1 RW Num US
E07 Nominal Elevator Speed rpm 1.00 to 4000.00 rpm 1480.14 rpm
39.48
rpm
RW Num US
E08
Open-Loop: Motor maximum
frequency
-214748364.8 to 214748364.7
54.8 Hz
RO Num US
RFC-A: Motor maximum speed
1644.6
rpm
RO Num US
RFC-S: Motor maximum speed
43.8 rpm RO Num US
E09
Open-Loop: Over Speed
Threshold
0.0 to 550.0 Hz
0.0 Hz RW Num PT US
RFC-A: Over Speed Threshold
0 to 40000 0 RW Num US
RFC-S: Motor Over Speed
Threshold
0.0 to 550.0 0.0 RW Num US
E10
Load Cell Compensation
Enable
Off (0) or On (1) Off (0) RW Bit US
E11 Load Cell Compensation Input ±100.0 % 0 RW Num US
E12
Load Cell Compensation Filter
Time Constant
0 to 32767 ms 100 ms RW Num US
E13 Load cell compensation torque ±VM_USER_CURRENT % 0.0 % RW Num US
E14
Inertia Compensation Mode
Select
None (0), Torque (2) None (0) RW Txt US
E15
Inertia Compensation Total
Inertia
0.00000 to 1000.00000 kgm² 0.00000 kgm² RW Num US
E16 Torque Per Amp
0.00 to 500.00 Nm/A
1.60
Nm/A
RO Num ND NC PT
E17 Inertia Compensation Torque
±1000.0 % RO Num ND NC PT
E18
Inertia compensation
acceleration
-1073741.824 to 1073741.823
mm/s² x100
RO Num ND NC PT
E19 Load Cell Compensation Offset ±100.0 % 0.0 % RW Num US
E20
Load Cell Compensation
Scaling
0.000 to 32.767 1.000 RW Num US
E30 Change of Direction Counter -2147483648 to 2147483647
RO Num ND NC PT PS
E31 Change of Direction Limit 0 to 65535 0 RW Num US
E32 Change of Direction Control 0 to 255 0 RW Num NC PT
RW Read / Write RO Read-only Bit Bit parameter Txt Text string Date Date parameter Time Time parameter
Chr
Character
parameter
Bin Binary parameter IP IP address Mac MAC address Ver Version number SMP
Slot, menu,
parameter
Num Number parameter DE Destination ND No default value RA Rating dependent NC Non-copyable PT Protected
FI Filtered US User save PS Power-down save