Safety
information
Product
information
Mechanical
installation
Electrical
installation
Getting
started
User Menu A Commissioning
Advanced
Parameters
Diagnostics Optimization CT MODBUS RTU Technical Data
242 Installation and System Design Guide
Issue Number: 1
8.20 Menu Z: Menu A Set-up
Menu Z is provided to allow the user to customise Menu A Set-up to hold the relevant parameters for the application allowing quick access for Set-
up, Commissioning, Tuning and Diagnostics.
By default User Menu A has been setup to cover the most typical applications and briefly detailed below.
User Menu A parameters Detail Sequential step
A01 - A03 Security, access and cloning Initial access and cloning
A04 - A09 Monitoring parameters output voltage current power speed Monitoring once cloned
A10 - A11 Elevator control interface Connection to lift controller
A12 - A17
Parameters for set-up of motor encoder, Default and auto configuration
SC.EnDat, Open loop parameters hidden
- Encoder set-up
A18 - A27 Parameter for set-up of the motor, Open loop RFC-A or RFC-S - Motor set-up
A28 - A34 Elevator mechanical system parameters, sheave, roping, gearbox, speed - Mechanical set-up
A35 - A46 Profile parameters and speeds - Profile
A47 - A48 Brake control delays - Brake control
A49 - A54 Speed current loop gains - Tuning control loop
A55 - A61 Start optimization for geared and gearless systems - Start locking, optimization
Parameter
Range(Ú) Default(Ö)
Type
Open-Loop RFC-A RFC-S Open-Loop RFC-A RFC-S
Z01 Parameter A01 Set-up A00 to AC99 H02 RO Num PT US
Z02 Parameter A02 Set-up A00 to AC99 B01 RW Num PT US
Z03 Parameter A03 Set-up A00 to AC99 N01 RW Num PT US
Z04 Parameter A04 Set-up A00 to AC99 J22 RW Num PT US
Z05 Parameter A05 Set-up A00 to AC99 J23 RW Num PT US
Z06 Parameter A06 Set-up A00 to AC99 J39 J40 RW Num PT US
Z07 Parameter A07 Set-up A00 to AC99 J59 RW Num PT US
Z08 Parameter A08 Set-up A00 to AC99 J60 RW Num PT US
Z09 Parameter A09 Set-up A00 to AC99 J61 RW Num PT US
Z10 Parameter A10 Set-up A00 to AC99 H11 RW Num PT US
Z11 Parameter A11 Set-up A00 to AC99 H12 RW Num PT US
Z12 Parameter A12 Set-up A00 to AC99 A00 C01 RW Num PT US
Z13 Parameter A13 Set-up A00 to AC99 A00 C02 RW Num PT US
Z14 Parameter A14 Set-up A00 to AC99 A00 C03 RW Num PT US
Z15 Parameter A15 Set-up A00 to AC99 A00 C04 RW Num PT US
Z16 Parameter A16 Set-up A00 to AC99 B10 A00 C13 RW Num PT US
Z17 Parameter A17 Set-up A00 to AC99 B12 C12 RW Num PT US
Z18 Parameter A18 Set-up A00 to AC99 B02 RW Num PT US
Z19 Parameter A19 Set-up A00 to AC99 B03 RW Num PT US
Z20 Parameter A20 Set-up A00 to AC99 B05 RW Num PT US
Z21 Parameter A21 Set-up A00 to AC99 B06 A00 RW Num PT US
Z22 Parameter A22 Set-up A00 to AC99 B07 RW Num PT US
Z23 Parameter A23 Set-up A00 to AC99 B09 A00 B09 RW Num PT US
Z24 Parameter A24 Set-up A00 to AC99 B16 RW Num PT US
Z25 Parameter A25 Set-up A00 to AC99 B13 RW Num PT US
Z26 Parameter A26 Set-up A00 to AC99 B11 RW Num PT US
Z27 Parameter A27 Set-up A00 to AC99 B26 RW Num PT US
Z28 Parameter A28 Set-up A00 to AC99 E01 RW Num PT US
Z29 Parameter A29 Set-up A00 to AC99 E02 RW Num PT US
Z30 Parameter A30 Set-up A00 to AC99 E03 RW Num PT US
Z31 Parameter A31 Set-up A00 to AC99 E04 A00 RW Num PT US
Z32 Parameter A32 Set-up A00 to AC99 E05 A00 RW Num PT US
Z33 Parameter A33 Set-up A00 to AC99 E07 RW Num PT US
Z34 Parameter A34 Set-up A00 to AC99 E08 RW Num PT US
Z35 Parameter A35 Set-up A00 to AC99 G13 RW Num PT US
Z36 Parameter A36 Set-up A00 to AC99 G14 RW Num PT US
Z37 Parameter A37 Set-up A00 to AC99 G15 RW Num PT US
Z38 Parameter A38 Set-up A00 to AC99 G16 RW Num PT US
Z39 Parameter A39 Set-up A00 to AC99 G18 RW Num PT US