EasyManua.ls Logo

Nidec E300 Series - Menu AC: DCP

Nidec E300 Series
314 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Safety
information
Product
information
Mechanical
installation
Electrical
installation
Getting
started
User Menu A Commissioning
Advanced
Parameters
Diagnostics Optimization CT MODBUS RTU Technical Data
244 Installation and System Design Guide
Issue Number: 1
8.21 Menu AC: DCP
Parameter
Range(Ú) Default(Ö)
Type
Open-Loop RFC-A RFC-S Open-Loop RFC-A RFC-S
AC01 DCP Keypad Language Deutsch (0), English (1) Deutsch (0) RW Txt US
AC02 DCP Wire break Trip Enable Off (0) or On (1) On (1) RW Bit US
AC03 DCP4 Remaining Distance Ref -2147483648 to 2147483647 mm 0 mm RW Num
AC04
DCP4 Time Delay
Compensation
0 to 100 ms 50 ms RW Num US
AC05 DCP4 Interpolation Enable Off (0) or On (1) Off (0) RW Bit US
AC06
DCP4 Remaining Distance
Time
0 to 10000 ms 0 ms RW Num US
AC07 DCP Position Window 0 to 3000 mm 5 mm RW Num US
AC08 DCP Speed Window 0 to 3000 mm/s 5 mm/s RW Num US
AC09 DCP Window Time 0 to 5000 ms 500 ms RW Num US
AC10 DCP Enable 16bit Distance 15Bit Distance (0), 16Bit Distance (1) 15Bit Distance (0) RW Txt US
AC17 DCP 1C Message Count 0 to 65535
RO Num ND NC
AC18 DCP Last 1C Message ID 0 to 65535
RO Num ND NC
AC19
DCP Process Data Messages
Per Second
0 to 65535
RO Num ND NC
AC20 DCP I7 Stopping Distance 0 to 65535 mm
RO Num ND NC
AC21 DCP I7 Total Distance 0 to 65535 mm
RO Num ND NC
AC22 DCP I7 Set Distance 0 to 65535 mm
RO Num ND NC
AC23 DCP I9 Drive Distance -2147483648 to 2147483647 mm
RO Num ND NC US
AC24 DCP I9 Controller Distance -2147483648 to 2147483647 mm
RO Num ND NC US
AC25
DCP4 Remaining Distance
Control
0 to 65535 mm
RO Num ND NC
AC26
DCP4 Remaining Distance
Drive
0 to 65535 mm
RO Num ND NC
AC27 Profile Stopping Distance 0 to 65535 mm
RO Num ND NC
AC28
DCP Calculated Sheave
Diameter
0 to 65535 mm
RO Num ND NC
AC29 DCP Selected Speed Word 0 to 65535
RO Num ND NC
AC30 DCP Software Active -2147483648 to 2147483647
RO Num ND NC US
AC31 DCP Travel Type DCP3 (3), DCP4 (4)
RO Txt ND NC
AC32 DCP RX Byte 1 0 to 65535
RO Num ND NC
AC33 DCP RX Byte 2 And 3 0 to 65535
RO Num ND NC
AC34 DCP RX Byte 4 And 5 0 to 65535
RO Num ND NC
AC35 DCP RX Byte 6 0 to 65535
RO Num ND NC
AC36 DCP TX Byte 1 0 to 65535
RO Num ND NC
AC37 DCP TX Byte 2 And 3 0 to 65535
RO Num ND NC
AC38 DCP TX Byte 4 And 5 0 to 65535
RO Num ND NC
AC39 DCP TX Byte 6 0 to 65535
RO Num ND NC
AC40 E300 Profile Output Speed ±VM_AMC_SPEED UU/ms
RO Num ND NC PT FI
AC41 E300 Position ±VM_AMC_POSITION UU
RO Num ND NC PT
RW Read / Write RO Read-only Bit Bit parameter Txt Text string Date Date parameter Time Time parameter
Chr
Character
parameter
Bin Binary parameter IP IP address Mac MAC address Ver Version number SMP
Slot, menu,
parameter
Num Number parameter DE Destination ND No default value RA Rating dependent NC Non-copyable PT Protected
FI Filtered US User save PS Power-down save