8.3 Menu D: Brake
Menu D Brake allows the user to setup the Elevator motors brake control parameters
In addition to the standard motor brake control parameters Menu D Brake also allows the user to setup the braking resistor protection and motor
brake contact monitoring used for Unintended Car Movement (UCM).
• Motor brake set-up and limits • Motor brake control
• Motor brake contact monitoring for 4 x motor brakes with error detection • Low voltage braking control setup
• Braking resistor electronic thermal protection (external braking resistor protection
recommended to protect both braking resistor and braking circuit against risk of fire)
Parameter
Range(Ú)Default(Ö)
Type
Open-Loop RFC-A RFC-S Open-Loop RFC-A RFC-S
D01 Motor Magnetized Indication Off (0) or On (1) RW Bit US
D02 Motor Torque Ramp Time 0 to 32767 ms 100 ms RW Num US
D03 Brake Control Output Off (0) or On (1)
RO Bit ND NC PT
D04 Brake Control Relase Delay 0 to 10000 ms 500 ms RW Num US
D05 Brake Control Apply Delay 0 to 10000 ms 500 ms RW Num US
D06
Brake Control: Upper Current
Threshold
0 to 200 %
10 % RW Num US
D07
Brake Control: Lower Current
Threshold
0 to 200 % 10 % RW Num US
D08
Open-Loop: Brake Control: Brake
Release Frequency
0.0 to 20.0 Hz
1.0 Hz RW Num US
D09
Open-Loop: Brake Control: Brake
Apply Frequency
0.0 to 20.0 Hz
2.0 Hz RW Num US
RFC-A: Brake Control: Brake Apply
Speed
0 to 200 5 RW Num US
RFC-S: Brake Control: Brake Apply
Speed
0 to 200 5 RW Num US
D10 Reference On Off (0) or On (1)
RO Bit ND NC PT
D11 Brake Contact Monitoring Select
None (0), 1 (1), 1 & 2 (2), 1, 2 & 3 (3),
1, 2, 3 & 4 (4), 1 + UCM (5), 1 & 2 + UCM (6),
1, 2 & 3 + UCM (7), 1, 2, 3 & 4 + UCM (8)
None (0) RW Txt US
D12 Brake Contact Monitoring Input 1 Off (0) or On (1)
RW Bit US
D13 Brake Contact Monitoring Input 2 Off (0) or On (1)
RW Bit US
D14 Brake Contact Monitoring Time 1.0 to 10.0 3.0 RW Num US
D15 Braking Resistor Rated Power 0.000 to 99999.999 kW 0.000 kW RW Num US
D16
Braking Resistor Thermal Time
Constant
0.000 to 1500.000 s 0.000 s RW Num US
D17
Braking Resistor Thermal
Accumulator
0.0 to 100.0 %
RO Num ND NC PT
D18 Braking Resistor Resistance 0.00 to 10000.00 0.00 RW Num US
D19 Braking IGBT Lower Threshold ±VM_DC_VOLTAGE_SET V
200V drive: 390 V, 400V drive: 780 V
575V drive: 930 V, 690V drive:
1120 V
RW Num US
D20 Braking IGBT UpperThreshold ±VM_DC_VOLTAGE_SET V
200V drive: 390 V, 400V drive: 780 V
575V drive: 930 V, 690V drive:
1120 V
RW Num US
D21 Low Voltage Braking IGBT Threshold ±VM_DC_VOLTAGE_SET V 0V RW Num US
D22
Low Voltage Braking IGBT Threshold
Select
Off (0) or On (1) Off (0) RW Bit
D30 Brake Contact Monitoring Input 3 Off (0) or On (1)
RW Bit ND NC
D31 Brake Contact Monitoring Input 4 Off (0) or On (1)
RW Bit ND NC
D32 Low Torque Ramp Down Time 0 to 32767 ms 0 ms RW Bit ND NC
RW Read / Write RO Read-only Bit Bit parameter Txt Text string Date Date parameter Time Time parameter
Chr Character parameter Bin Binary parameter IP IP address Mac MAC address Ver Version number SMP Slot, menu, parameter
Num Number parameter DE Destination ND No default value RA Rating dependent NC Non-copyable PT Protected