2.4.1 Power and current ratings (derating for switching frequency and temperature)
Table 2-5 Nominal output current @ 40 °C (104 °F) ambient
Model
Nominal rating Nominal output current (A) for the following switching frequencies
kW hp
Peak
current
3kHz 4kHz 6kHz 8kHz 12kHz 16kHz
200 V
03200106 2.2 3.0 18.6 10.6 10.1 9.5
04200137 3.0 3.0 24 13.7 13 12.3
04200185 4.0 5.0 32.4 18.5 17.6 16.7
05200250 5.5 7.5 43.8 25 23.8 22.5
06200330 7.5 10 57.8 33.0 31.4 29.7
06200440 11 15 77 44.0 41.8 39.6
07200610 15 20 107 61 58 54.9
07200750 18.5 25 132 75 71.3 67.5
07200830 22 30 146
83
78.9 74.7
08201160 30 40 203
116
110 104
08201320 37 50 231
132
125 119
09201760 45 60 308
176
167 158
09202190 55 75 383
219
208 197
10202830 75 100 496
283
269 255
10203000 90 125 525
300
285 270
400 V
03400062 2.2 3.0 11
6.2
5.9 5.6
03400078 3.0 5.0 14
7.8
7.4 7
03400100 4.0 5.0 18
10
9.5 9
04400150 5.5 10 27
15
14.3 13.5
04400172 7.5 10 31
17.2
16.3 15.5
05400220 11 20 48
22
25.7 24.3
05400270 11 20 48
27
25.7 24.3
05400300 15 20 53
30
28.5 27
06400350 15 25 62
35
33.3 31.5
06400420 18.5 30 74
42
39.9 37.8
06400470 22 30 83
47
44.7 42.3
07400660 30 50 116
66
62.7 59.4
07400770 37 60 135
77
73.2 69.3
07401000 45 75 175
100
95 90
08401340 55 100 235
134
127 121
08401570 75 125 275
157
149 141
09402000 90 150 350
200
190 180
09402240 110 150 385
220
213 202
10402700 132 200 473
270
257 243
10403200 160 250 543
310
304 272
11403770 185 300 660
377
358 339
11404170 200 350 730
417
11404640 250 400 787
464 450