Setting Parameters To Default Values
42-02-2M01 A1 4-5
4
Motion 4000
• RSTA - RSTB: Reset. If the elevator is running when reset, the controller will drop the
safety relay and bring the elevator to an immediate stop. The elevator will then go to the
next landing, self-check, and resume service if warranted. Existing calls are lost if the com-
puter is reset.
• N, S, +, - Push Buttons: Parameter review and entry. Access and function depend on the
positions of the Function switches. Generally:
• N = Next. Moves the cursor.
• S = Select or Save.
• +/- = Increment/Decrement.
Setting Parameters To Default Values
There are occasions when it is necessary to reset system parameters to default values:
• MC-MPU software is changed.
• RAM memory is corrupted (lightning strikes can sometimes cause this)
To reset to default values:
1. Place the car on Machine Room Inspection.
2. Place function switches F1, 3, 5, and 7 in the Up position.
3. Press all four push buttons (N, S, +, -) at the same time.
After resetting parameters to their defaults, you will need to set up system parameters again.
INSP Inspection: The car is on inspection operation.
IND Independent Service: The car is on independent service.
HS High Speed: The car is running at high speed.
DLK Doors Locked: The door lock contacts are made.
SAF ON Safety On: The safety circuit is made.
Table 4.2 HC-MPU / HC-MPU-2 Board Indicators
Indicators Description