Installation
2-20 42-02-2M01 A1
1. Select No action (alternatively, enter a value of 0) in Parameter mm00 and press
Enter.
2. The display shows No Action.
Accessing Diagnostics
The drive has a status LED on the front of the drive just below the keypad. The status LED will
remain solidly on if no fault has occurred and will flash if the drive has tripped.
Trip Numbers:
Parameter L29 through L38 store the 10 most recent trips, with L29 as the most recent
and L38 as the oldest.
Sub-Trip Numbers:
Some trips have sub-trip numbers which provide more detail on the possible cause for a
trip. If a trip has a sub-trip number, its value is stored in parameter L61 through L70
where L61 correlates to L29 while L70 correlates with L38. If the trip does not have a sub-
trip number, zero will be stored in the sub-trip log.
AC Drive Setup
Using the programming record for the job, program the drive parameters. Refer to the Keypad
Operation section above to become familiar with saving parameters, defaulting parameters if
required, observing only parameters with non-default values, and the unique procedure used to
change the drive’s mode of operation.