1-2 Manual # 42-02-2M01 A1
Motion 4000 Traction Elevator Control Overview
A Motion 4000 controller order may include:
Controller: Configured according to job survey, field programmable.
Cartop station: Interface between car-mounted equipment and the car controller.
Serial panel option: Converts car panel analog button data to serial data stream.
Optional CAN node boards and wiring for serial hall call.
User Interface: Standard, controller mounted keypad/display, optional hand-held key-
pad/display to set controller parameters, optional mView PC application.
Table 1.1 Specifications
Maximum car speed 500 FMP, 2.5 m/s
Configuration Simplex, Duplex, Group to 6 cars
Landings 32 landings, 64 openings maximum
Motor control Control Techniques E300 AC drives
Landing/Positioning system Encoded magnetic tape or perforated steel tape
Call Registration Serial or Discrete COP, Serial or Discrete Hall Call
Power requirement 208 – 600 VAC, 50/60 Hz, 3-phase
Environment 32 - 104º F, 0 - 40º C; Humidity 95% non-condensing
*Standard enclosure (includes legs) 42” w x 72” h x 16” d (1067 x 1829 x 406 mm) with knock-outs
Available NEMA enclosures NEMA 4, 4X, 12
* Variations available
AC Drive
CAN Hub & Power distribution
MPU Board
Control Board
Motion Processor Interface Board
Panel Mount Terminals
Universal I/O Boards
Standard cabinet dimensions:
16” x 42” x 72” (406 x 1067 x 1829 mm)
including legs (12” (305 mm).