44
NITTY GRITTY.IT
make it shine
B
C
A
CLINOX PRO • AIR • POWER • SURFACE
USER MANUAL
The polishing process requires a greater
amount of electrolyte solution than pickling.
Always keep the felt/brush well moistened
with the electrolyte solution to avoid
overheating and a consequent signicant
reduction in its working life; if there
are obvious signs of wear, replace the
component immediately.
If you increase the power and/or voltage
during processing, the electrolyte solution
evaporates more quickly; make sure that
the felt or brush is always wet.
Never use an insert without its matching
felt; the insert must never be placed in
direct contact with the steel workpiece.
When carrying out cleaning/polishing, keep
the brush perpendicular to the weld and
never press the carbon bristles excessively
against the surface to be treated (C).
For best results, periodically adjust the PTFE
sleeve of the brush to leave approximately
10-15 mm of carbon bres exposed.
Felts (A) are particularly suitable for large welds, while brushes (B) are suitable for hard-to-reach welds.
Start cleaning/polishing by positioning the felt/brush on the stainless steel workpiece.
Pass the felt/brush over the weld by applying light pressure and continue the process until each sign of oxidation is
completely removed. Sparks and foam may form at the contact point between the felt/brush and the weld during processing.
This is perfectly normal.
If necessary, use the and + buttons on the control panel to adjust the output voltage and to obtain better results (if you
change operating mode, the voltage returns to the default level preset by the manufacturer).
NO!