A
E
B
C
D
D
A
B
C
D
GC2e Wireless Security System | Installation and Programming Guide
©2020 Nortek Security & Control LLC. All rights reserved. 18 2GIG is a registered trademark of Nortek Security & Control LLC.
Figure 13 Power Supply Wiring
NOTE: In the United States, wiring routed inside walls, ceilings,
and oors must comply with requirements of ANSI/NFPA 70:
Naonal Electrical Code (NEC) and local building codes. For
wiring from the output of the 2GIG Class II Power Supply, wiring
rated CL2, CL2X, CL2R, or PLTC is recommended to sasfy these
requirements. If this wiring is installed in an air plenum (space
used for environmental air exchange) it must be rated CL2P
(plenum-rated).
Figure 14
Connecting Battery and Closing Panel
3. Spread the retaining bracket ears and plug the Control
Panel’s power supply into the unswitched wall outlet. Slots
are provided on the bracket to secure the power supply
with a zip-e.
4. Aer about ve (5) seconds, the Control Panel indicates
that power has been applied. If the Control Panel does not
power up, check the power supply polarity.
Figure 15
Securing the Power Supply
Control Panel and Power Supply Mounting
Aer all the wiring complete, follow these steps to power up the
Control Panel:
1. Place the boom of the Control Panel over the lower lip
of the backplate and ip the Control Panel upwards. Then
push the Control Panel over the mounng bracket unl it
snaps into place, then secure it with the retaining screw.
2. Peel o the adhesive backing from the power supply
retaining bracket and aach the bracket to the outlet with a
wall plate screw.
NOTE: In the United States (and other countries where it is
required), use the power supply retaining bracket. In Canada, the
power supply retaining bracket is not required.
1 Place the screw here for a bracket on a standard style outlet.
2 Place the screw here for a bracket on a decora style outlet.
A Connect battery
B Align mounting plate tabs inside of console bottom edge
C Swing console up and snap into the mounting plate
D Secure console with two screws in retaining mode
E Align face plate and press into place
A Left Terminal 14 VDC (+) C 14 VDC (+) Terminal 1
B Right Terminal 14 VDC (-) D 14 VDC () Terminal 2
Installation