Programming Questions
Q1: RF Sensor Programming
To learn about RF sensor programming, see “Wireless (RF)
Sensor Programming” on page 38.
Q2: Wired Sensor Programming
To learn about wired sensor programming, see “Wired
Sensor Programming” on page 41.
Q3: RF Key Fob Programming
To learn about RF key fob programming, see “Wireless (RF)
Keyfob Programming” on page 44.
Q4: RF Keypad Programming
To learn about RF keypad programming, see “Wireless (RF)
Keypad Programming” on page 46.
Q5: Exit Delay, in Seconds (45-120)
DEFAULT: 60 seconds
The default minimum seng of 60 seconds is required for
ANSI/SIA CP-01 compliance. The delay me can be increased
without aecng compliance.
The exit delay mer can be set to a value between 45 to 120
seconds.
• The default seng 60 sets the exit delay to 60 seconds.
• To change the exit delay mer, enter a value between
45‐120 seconds.
Q6: Entry Delay 1, in Seconds (30-240)
DEFAULT: 30 seconds
The default minimum seng of 30 seconds is required for
ANSI/SIA CP‐01 compliance.
NOTE: For compliance with ANSI/SIA CP‐01, the total
number of minutes for the combinaon of Q6: Entry Delay 1
and Q35: Abort Window Dialer Delay cannot exceed one (1)
minute.
The mer for Entry Delay 1 can be set to a value between 30
to 240 seconds.
• The default seng 30 sets the mer to 30 seconds.
• To change the seng, enter a value between 30‐240
seconds.
Q7: Entry Delay 2, in Seconds (30-240)
DEFAULT: 45 seconds
The default minimum seng of 45 seconds is required for
ANSI/SIA CP‐01 compliance.
NOTE: For compliance with ANSI/SIA CP‐01, the total number
of minutes for the combinaon of Q7: and Q35:
Abort Window Dialer Delay cannot exceed one (1) minute.
The mer for Entry Delay 1 can be set to a value between
30-240 seconds:
• The default seng of 45 sets the mer to 45 seconds.
• To change the mer seng, enter a value between
30‐240 seconds.
Q13: 2-Way Voice (0-2)
DEFAULT: (1) Stay On Line
The Control Panel supports two (2)-way voice communicaons
between the subscriber and the Central Staon operator over
the LTE (Cellular) Radio Module (if installed) aer an alarm has
been reported.
• The (1) Stay On Line allows two (2)-way audio over the cell
radio.
• Selecng (2) Stay On Line, Including Fire and CO Alarms
allows 2-way audio over cell radio during re and CO alarms.
• To turn o the two (2)-way audio feature OFF, select (0)
Disabled.
When the Control Panel connects with the operator, it will beep
once per second (every 6 seconds with a cell radio connecon).
The beep alternates between two tones and indicates the
Control Panel is waing for a session command. If the operator
fails to issue a command within one (1) minute (or three (3)
minutes if using the cell radio connecon), the call is terminated.
Once the operator presses a command opon, the beeps will
stop and a ve (5)-minute audio session will start (or three (3)-
minute audio session if using the cell radio connecon).
When two (2)-way voice communicaons have been established,
the Central Staon operator can use the following telephone
keys to control the communicaons. Each me the operator
uses a command key, the session is extended for ve addional
minutes (three minutes with a cell radio connecon). During the
last minute of communicaons, the system beeps two (2) me s
every 15 seconds to indicate that me is running out.
• Tap 1 to enable Talk mode one (1)-way communicaon from
the Central Staon to the premises and allows the operator
to talk.
• Tap 2 to enable VOX mode two (2)-way communicaons
from the Central Staon to the premises.
• Tap 3 to enable Listen mode one (1)-way communicaon
from the premises to the Central Staon.
• Tap 7 to extend the session ve (5) minutes without
changing the mode of operaon.
• Tap 9 to end the audio session an terminate the call.
Q14: Silent Panic/Burglary Listen Only
DEFAULT: (1) Enabled
The Control Panel supports audio listen-in of the subscriber
premises from the Central Staon aer a silent panic (police
emergency), silent burglary, or duress alarm has been reported.
• The default seng (1) Enabled allows the Central Staon to
use listen-in over audio aer a silent panic, silent burglary,
or duress alarm.
• This opon is permanently set and cannot be disabled.
Control Panel Programming