GC2e Wireless Security System | Installation and Programming Guide
©2020 Nortek Security & Control LLC. All rights reserved. 38 2GIG is a registered trademark of Nortek Security & Control LLC.
Installer Programming
Account Registration
Register the account to enroll the Control Panel with the remote
service provider’s Central Staon.
Typically, the account registraon data is created with the service
installaon contract and then stored in a database managed by
the Central Staon. The data includes items such as the customer
name, address, and the Central Staon telephone number, and the
account number assigned to the Control Panel.
If you will be installing the 2GIG Go!Bridge IP Communicator,
addional registraon informaon is required. For details, see
the Installaon Instrucons included with the Go!Bridge IP
Communicator.
Wireless (RF) Sensor Programming
The Control Panel can be programmed with up to 60 RF sensors
of dierent types. In addion to the 60 mul- purpose RF sensors,
you can also program eight (8) RF remote control key fobs and four
(4) RF remote control keypads into the system.
RF sensors # 01‐48 and #63‐74 report as wireless zones 01‐ 60.
Programming quesons for RF sensor programming include:
• Q1: Select RF Sensor Number. Select sensor number 01-48 or
63-74.
• Q: Select RF Sensor # Type. Select (01) Exit/Entry 1, (02)
Exit/Entry 2, (03) Perimeter, and so on. For opons, see
“Zone Numbering” on page 32.
• Q: Select RF Sensor # Equipment Type. Some sensor types
ask for the equipment type, others do not. See “Q: Select
RF Sensor # Equipment Type” on page 40.
• Q: Select RF Sensor # Equipment Code. Select the four (4)-
digit equipment code for the sensor model. See “Equipment
Codes” on page 37.
• Q: Enter RF Sensor # Other Equipment Code. If you select
(0000) Other in the previous queson, you must enter this
code.
• Q: Enter RF Sensor # Serial #. Enter the serial number
(typically a label on the sensor or its packaging) or tap Shi
then Learn on the panel. Then trip the sensor to transmit
the serial number to the panel.
• Q: Select RF Sensor # Equipment Age. Specify whether the
sensor is (0) New or (1) Exisng.
• Q: Select RF Sensor # Loop Number. Specify the
appropriate loop number(s) for the sensor. See “Q: Select RF
Sensor # Loop Number (1 to 3)” on page 40.
• Q: Select RF Sensor # Dialer Delay. Specify whether to use
delayed or instant digital communicator reports for the
sensor. The delay me is set on the Dialer Abort screen.
• Q: Construct RF Sensor # Voice Descriptor. Specify the
name assigned to the sensor that is announced if this
feature is programmed.
• Q: Select RF Sensor # Reports. Specify (0) Disabled or (1)
Enabled whether or not RF sensors trigger a report to the
Central Staon.
• Q: Select RF Sensor # Supervised. Specify whether or not
the Control Panel checks for status reports from the sensor.
• Q: RF Sensor # Chime. Select voice announcement and
chime opons for the sensor.
2GIG eSeries Equipment Codes
Wireless Zones - GC2e & GC3e eSensor Equipment Codes
When programming eSensors (Wireless Sensors & Keyfobs) the equipment code must match the sensor being installed.
*Available soon for GC2e
**Available soon for GC2e & GC3e
Code Description
2058** eSeries Smoke Detector (USA) (Use for all loops (1 2 3)
2061* eSeries Tilt Sensor
2065* eSeries Flood Sensor
2067* eSeries Repeater
2069* eSeries FireFighter SMKT/CO Listener
2070* eSeries Water Sensor
2860 eSeries CO Detector (USA)
2862 eSeries Thin Door/Window Contact
2863 eSeries Recessed Door Contact
2864 eSeries Glass Break Detector
2865 eSeries Outdoor Door/Window Sensor
2866 eSeries Key FOB
2868* eSeries Panic
2869 eSeries PIR with Pet Immunity
2873* eSeries Takeover Module
Note: For sensors with multiple loops, the eSeries equipment codes must be used for all programmed loops.