GC2e Wireless Security System | Installation and Programming Guide
©2020 Nortek Security & Control LLC. All rights reserved. 52 2GIG is a registered trademark of Nortek Security & Control LLC.
Control Panel Programming
Q35: Abort Window Dialer Delay (0-2)
DEFAULT: (1) 30 Seconds
The default minimum seng for ANSI/SIA CP-01 compliance is 30
seconds.
The delay me can be increased to 45 seconds without aecng
ANSI/SIA CP-01 compliance only if the combinaon of Q35 and Q6
or Q7 does not exceed one (1) minute.
NOTE: The dialer delay can be disabled for each sensor without
aecng ANSI/SIA CP-01 compliance. See “RF Sensor Programming
Quesons” on page 39.
The system delays calling the Central Staon to allow the user
enough me to cancel a false alarm before it is reported.
The default seng is (1) 30 Seconds.
To change the seng, select (0) 15 Seconds or (2) 45 Seconds.
Q36: Burglary Bell Cutoff (0 to 4)
DEFAULT: (0) 4 Minutes
When a burglary alarm is triggered, the bell will sound unl the
burglary bell cuto me expires.
The default seng for the burglary bell cuto is (0) 4 Minutes.
To change the cuto me, select an opon below.
Burglary Bell Cutoff Time
(0) 4 Minutes
(1) 8 Minutes
(2) 12 Minutes
(3) 16 Minutes
(4) Unlimited
NOTE: The 24-hour Auxiliary Alarm Zone (08) does not follow the
burglary bell cuto me and will sound the Control Panel’s local
alarm unl a User Code is entered. The Auxiliary Alarm Zone does
not trigger the external siren (if used).
Q37: Fire Bell Cutoff (0-4)
DEFAULT: (0) 4 Minutes
When a re alarm is triggered, the bell sounds unl the re bell
cuto me expires.
The default seng (0) 4 Minutes sets the burglary bell cuto
to four (4) minutes.
To change the re bell cuto me, select an opon below:
NOTE: Aer the AC power alert is displayed or clears, the
AC power loss report or AC power restore report can be sent to
the Central Staon immediately, or at a random me, see Q39:
Random AC Loss Report Time.
NOTE: The Control Panel’s AC Power Icon immediately displays the
power status. See AC Power ON/OFF” on page 25.
Q39: Random AC Loss Report Time (0-1)
DEFAULT: (1) Enabled
This feature allows the system to report AC power loss and AC
power restore at a random me of up to 45 minutes aer the
event occurs. This helps to reduce Central Staon congeson due
to a wide-spread power outage aecng many Control Panels at
once. The random AC power status report mer is triggered based
on the me set by Q38: Random AC Loss Report Time.
The default seng (1) Enabled turns this feature ON.
To turn this feature OFF, select (0) Disabled.
NOTE: The installer code must be unique from the master user
code and all other user codes.
Q43: Installer Code (4 or 6 Digits)
DEFAULT: 1561
The installer code is a unique code that installaon technicians use
to access the Installer Toolbox on the Control Panel.
The default installer code is 1561.
To change the installer code, enter a new four (4)- digit code.
IMPORTANT: If you change the installer code, always write it
down so that you can access the system later.
Q44: Lock Installer Programming (0-2)
DEFAULT: (0) Disabled
The installer programming lockout feature is provided to prevent
takeovers. The Control Panel can be set to limit an installer’s access
to programming quesons aer a period of 48 hours. The 48-Hour
Lockout mer starts when the installer exits System Conguraon
mode.
Three (3) opons are available:
Unlimited full access to programming (no lockout).
Limited access to programming aer 48 hours.
No access to programming aer 48 hours The default seng
(0) Disabled selects unlimited full access to programming (no
lockout).
To deny access to programming aer 48 hours, select (1) No
Access to Programming.
If you select (2) Limited Access to Programming the installer will
be able to view, but not change the following aributes aer the
system has run for 48 hours, the Central Staon phone number,
Central Staon account number, lock installer programming,
download ID, and default lockout elds.
Aer the 48 hour lockout mer has locked out the system, the
mer can be reset through the cell radio or PC download by
remotely seng this queson to (0) or (2). Seng the opon to
(0) or (2) will restart the 48 hour lockout mer.
Fire Bell Cutoff Time
(0) 4 Minutes
(1) 8 Minutes
(2) 12 Minutes
(3) 16 Minutes
(4) Unlimited
Q38: Time to Detect AC Loss, in Minutes (0-30)
DEFAULT: (10) 10 Minutes
When AC power is lost, they system displays a power loss alert
aer the specied me length. When power is restored, the alert is
automacally cleared aer one (1) minute.