Q16: Police Emergency Key (0-2)
DEFAULT: (1) Audible
The Control Panel’s panic emergency buon acon can be
programmed. The panic emergency buon is displayed by
pressing the
buon.
The default (1) Audible allows the panic emergency
buon to sound an audible alarm.
For silent acvaon, select (2) Silent Panic.
To not display the panic emergency buon, select (0)
Disabled.
NOTE: Seng this programming queson for (2) Silent Panic
makes the Police buon on all RF keypads silent also.
Q17: Fire Emergency Key (0-1)
DEFAULT: (1) Audible
The Control Panel’s re emergency buon can be enabled or
disabled. The re emergency buon is displayed by pressing
the Control Panel’s buon.
The default seng (1) Audible allows the re
emergency buon to sound an audible alarm.
To disable and not display the re emergency buon,
select (0) Disabled.
Q18: Emergency Key (0-1)
DEFAULT: (1) Audible
The Control Panel’s emergency buon can be enabled or
disabled. The panel’s emergency buon is displayed by
pressing the Emergency
buon on the panel.
The default seng (1) Audible sounds an audible alarm
when the buon is pressed.
To disable this buon, select (0) Disabled.
NOTE: If all three (3) Emergency buons are disabled, the
Control Panel displays a message when its Emergency
buon is pressed.
Q19: Quick Arming (0-1)
DEFAULT: (1) Enabled
Quick arming allows the subscriber to arm the system
without having to enter a user code. If Open/Close Reports
are being sent, quick arming is reported as User 0.
The default (1) Enabled allows quick arming.
To turn o quick arming, select (0) Disabled.
Q20: Swinger Shutdown Count (1-6)
DEFAULT: (2) Two Trips
The minimum seng of (2) Two Trips is required for ANSI/
SIA CP‐01 compliance. This default seng can be increased
to three or more trips without aecng ANSI/SIA CP‐01
compliance.
An unwanted series of mulple faults (usually caused by a bad
contact or sensor) is called a “swinger. Swinger shutdown
sets the maximum number of alarms that any sensor or
hardwire loop can trigger during a single arming period.
NOTE: CO and Smoke detector alarms are not limited by the
swinger shutdown count. Other types of 24-hour zones are
limited by the swinger shutdown count.
The default seng (2) Two‐Trips sets the swinger
shutdown count at two (2) trips.
To change this count, select (1-6).
Q21: Siren Supervision Time (0-3)
DEFAULT: (0) Disabled
The wiring connecon to the external sounder can be
supervised. If the wiring to the sounder is cut for 15, 30, or 45
seconds, a bell trouble report can be sent to the Central Staon.
The default seng (0) Disabled turns external sounder
supervision OFF.
To supervise the external sounder wiring, select:
(1) 15 Seconds
(2) 30 Seconds
(3) 45 Seconds
Q22: CS Lack of Usage Notification Time
(0-255)
DEFAULT: 7 days
If this system has not been armed for a specied number of
days, inacvity reports can be sent to the Central Staon.
The default seng is 7 days.
To change the duraon, select a value between 1 to 255
days.
To turn this feature OFF, select 0 days.
Q23: Radio Modem Network Failure Time
(0-255)
DEFAULT: 30 Minutes
NOTE: LTE (Cellular) Radio Module must be installed to use this
funcon.
If the oponal LTE (Cellular) Radio Module loses its cellular
connecon, specify the amount of down me that must pass
before triggering a trouble condion.
The default seng is 30 minutes.
To specify a dierent amount of me, enter a value
between one (1) to 255 minutes.
To turn this feature OFF, select 0 minutes.
NOTE: Aer cellular service is restored for ve (5) minutes, the
trouble condion automacally clears.
Q24: Radio Modem Network Failure Causes
Trouble (0-1)
DEFAULT: (1) Enabled
NOTE: LTE (Cellular) Radio Module must be installed to use this
funcon.
Selects whether the Control Panel will sound and display
trouble if the oponal LTE (Cellular) Radio Module has lost its
cellular connecon. The trouble sounder can be silenced by the
user at the Control Panel (cell radio trouble is logged regardless
of this seng). When the cellular radio module connecon is
restored, the trouble indicaons automacally clear.
The default (1) Enabled allows radio module failure trouble
indicaons.
To turn o radio module failure trouble indicaons, select
(0) Disabled.