GC2e Wireless Security System | Installation and Programming Guide
©2020 Nortek Security & Control LLC. All rights reserved. 50 2GIG is a registered trademark of Nortek Security & Control LLC.
Control Panel Programming
Q16: Police Emergency Key (0-2)
DEFAULT: (1) Audible
The Control Panel’s panic emergency buon acon can be
programmed. The panic emergency buon is displayed by
pressing the
buon.
• The default (1) Audible allows the panic emergency
buon to sound an audible alarm.
• For silent acvaon, select (2) Silent Panic.
• To not display the panic emergency buon, select (0)
Disabled.
NOTE: Seng this programming queson for (2) Silent Panic
makes the Police buon on all RF keypads silent also.
Q17: Fire Emergency Key (0-1)
DEFAULT: (1) Audible
The Control Panel’s re emergency buon can be enabled or
disabled. The re emergency buon is displayed by pressing
the Control Panel’s buon.
• The default seng (1) Audible allows the re
emergency buon to sound an audible alarm.
• To disable and not display the re emergency buon,
select (0) Disabled.
Q18: Emergency Key (0-1)
DEFAULT: (1) Audible
The Control Panel’s emergency buon can be enabled or
disabled. The panel’s emergency buon is displayed by
pressing the Emergency
buon on the panel.
• The default seng (1) Audible sounds an audible alarm
when the buon is pressed.
To disable this buon, select (0) Disabled.
NOTE: If all three (3) Emergency buons are disabled, the
Control Panel displays a message when its Emergency
buon is pressed.
Q19: Quick Arming (0-1)
DEFAULT: (1) Enabled
Quick arming allows the subscriber to arm the system
without having to enter a user code. If Open/Close Reports
are being sent, quick arming is reported as User 0.
• The default (1) Enabled allows quick arming.
• To turn o quick arming, select (0) Disabled.
Q20: Swinger Shutdown Count (1-6)
DEFAULT: (2) Two Trips
The minimum seng of (2) Two Trips is required for ANSI/
SIA CP‐01 compliance. This default seng can be increased
to three or more trips without aecng ANSI/SIA CP‐01
compliance.
An unwanted series of mulple faults (usually caused by a bad
contact or sensor) is called a “swinger”. Swinger shutdown
sets the maximum number of alarms that any sensor or
hardwire loop can trigger during a single arming period.
NOTE: CO and Smoke detector alarms are not limited by the
swinger shutdown count. Other types of 24-hour zones are
limited by the swinger shutdown count.
• The default seng (2) Two‐Trips sets the swinger
shutdown count at two (2) trips.
• To change this count, select (1-6).
Q21: Siren Supervision Time (0-3)
DEFAULT: (0) Disabled
The wiring connecon to the external sounder can be
supervised. If the wiring to the sounder is cut for 15, 30, or 45
seconds, a bell trouble report can be sent to the Central Staon.
• The default seng (0) Disabled turns external sounder
supervision OFF.
• To supervise the external sounder wiring, select:
• (1) 15 Seconds
• (2) 30 Seconds
• (3) 45 Seconds
Q22: CS Lack of Usage Notification Time
(0-255)
DEFAULT: 7 days
If this system has not been armed for a specied number of
days, inacvity reports can be sent to the Central Staon.
• The default seng is 7 days.
• To change the duraon, select a value between 1 to 255
days.
• To turn this feature OFF, select 0 days.
Q23: Radio Modem Network Failure Time
(0-255)
DEFAULT: 30 Minutes
NOTE: LTE (Cellular) Radio Module must be installed to use this
funcon.
If the oponal LTE (Cellular) Radio Module loses its cellular
connecon, specify the amount of down me that must pass
before triggering a trouble condion.
• The default seng is 30 minutes.
• To specify a dierent amount of me, enter a value
between one (1) to 255 minutes.
• To turn this feature OFF, select 0 minutes.
NOTE: Aer cellular service is restored for ve (5) minutes, the
trouble condion automacally clears.
Q24: Radio Modem Network Failure Causes
Trouble (0-1)
DEFAULT: (1) Enabled
NOTE: LTE (Cellular) Radio Module must be installed to use this
funcon.
Selects whether the Control Panel will sound and display
trouble if the oponal LTE (Cellular) Radio Module has lost its
cellular connecon. The trouble sounder can be silenced by the
user at the Control Panel (cell radio trouble is logged regardless
of this seng). When the cellular radio module connecon is
restored, the trouble indicaons automacally clear.
• The default (1) Enabled allows radio module failure trouble
indicaons.
• To turn o radio module failure trouble indicaons, select
(0) Disabled.