— 8-11 —
2) Observing the Motor operation, press the plus (+) key several times.
[+],[-],[ENT]
333( 222)
STEP1
Pressing ,
SHIFT
-
+
-
+
• • •
As the responce index decreases, the movement of the Motor is getting crisply.
3) Keep pressing the plus (+) key, eventually the Motor starts hunting and stops.
[+],[-],[ENT]
233( 123)
STEP1
Pressing ,
SHIFT
-
+
-
+
• • •
4) Keep pressing the minus (-) key until the Motor stops hunting and starts moving.
[+],[-],[ENT]
253( 145)
STEP0.1
-
+
-
+
• • •
5) Set the “VG” value to 80% of displayed “VG” when a hunting is stopped.
4 × 0.8 = 3.2
6) Press the space key to change the resolution of “VG” setting value from 1.0 to 0.1.
[+],[-],[ENT]
263( 156)
STEP0.1
SP
7) Press the minus key till “VG” value reaches to 3.2.
[+],[-],[ENT]
263( 156)
STEP0.1
-
+
-
+
• • •
8) Press the enter key to store the “VG” value.
263( 156)
STEP0.1
VG3.2
:_
ENT
A colon ( : ) will appear to confirm the input.
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com