— 12-25 —
NS : Notch Filter, Secondary (secondary notch filter frequency)
Format : NS data
Data : 0, 10 ~ 500 [HZ] or /AJ (adjust mode)
Shipping set : 0
Default : 0
l NS data sets frequency of secondary notch filter.
l If “0” is specified, the 2nd stage notch filter will be set to OFF. In such a case the display shows
“SEC.NF.OFF.”
l If the data other than “0” (i.e., 10 ~ 500) is specified, the frequency sets to data.
l Command TS or ?NS reports the current setting.
l NS/AJ starts adjusting program.
« NW : Neglect Width
Format : NW data
Data : 0 ~ 4
Shipping set : 2
Default : 0
l RUN and HOS are rising edge-triggered inputs. To protect against chattering due to physical
contact, the NW parameter sets a timer length to confirm the input as the current level detection.
Timer = data × 2.8 [ms]
l “TS” or “?NW” command reports the current setting.
OE : Sequence Option Edit
Format : OE data
Data : * or &
Default : Not available
l OE changes the sequence code of a program already specified in a channel.
l When this command is entered under the following conditions, the sequence code that is set
previously to the specified channel will be changed to the data of this command.
◊ CH command specifies a channel to be programmed.
◊ The Driver Unit outputs “?” indicating that it is ready for a command.
l “data” indicates the sequence code. Adding the sequence code enables to execute the positioning
of next channel without selecting it externally.
◊ * After the positioning is over, “IPOS” signal is output and execute the next channel’s
program.
◊ & After the positioning is over, outputs “IPOS” signal and stops. Then executes the next
channel’s program when “RUN” command is input.
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com