8-12
8.3.3. Adjustment of Velocity Integrator Frequency (VI)
l The adjustment of velocity integrator frequency (VI) shall be conducted after the velocity gain
(VG) is adjusted.
1) Start “VI” adjusting program.
[+]
,[-],[ENT]
444( 333)
STEP1
_VI1
I /V J
ENT
A
(1)
(5)
(2)
(3)
(4)
The messages are shown on the left.
Inputting the plus (+) or minus (-) key
changes “VI” value.
(The “VI” value varries with an actual
load inertia and revolution speed.)
l Explanation of the messages
(1) Key function
and
-
+
SHIFT
: Pressing key one time increases 1 resolution of “VI.”
-
+
: Pressing key one time decreases 1 resolution of “VI.”
ENT
: Store “VI”
value in the memory and completes the
adjustment.
(2) Indicates present “VI” value.
(3) Indicates “VI” value changed by pressing plus (+) or minus (-) key.
(4) Response index number: The lower number denotes better response.
(5) Positioning index number: The rower number denotes quicker positioning.
Note : Changing “VI” step ((3)).
If you want to change the resolution of step, press space key or back space key.
Space key : Changes the step to 1/10 of present resolution.
(Pressing twice makes 1/100.)
Back space key: Changes the step to 10 times of present resolution.
(Pressing twice makes 100 times.)
2) Observing the Motor operation, press the plus (+) key several times.
[+]
,[-],[ENT]
333( 222)
STEP1
_VI3
Pressing ,
SHIFT
-
+
-
+
• • •
As the responce index decreases, the movement of the Motor is getting crisply.
3) Keep pressing the plus (+) key, till the Motor starts hunting and stops.
[+]
,[-],[ENT]
233( 123)
STEP1
_VI5
Pressing ,
SHIFT
-
+
-
+
• • •