8-13
4) Keep pressing the minus (-) key until the Motor stops hunting and starts moving.
[+],[-],[ENT]
253( 145)
STEP0.1
_VI4
-
+
-
+
5) Set the “VI” value to 80% of displayed “VI” when a hunting is stopped.
4 × 0.8 = 3.2
Input the space key to change the resolution of “VI” setting value from 1.0 to 0.1.
6) Press the minus key till “VI” value reaches to 3.2.
[+],[-],[ENT]
263( 156)
STEP0.1
_VI4
SP
7) Input the enter key to store the “VI” value.
[+],[-],[ENT]
263( 156)
STEP0.1
_VI3.2
-
+
-
+
8) A colon ( : ) will appear to confirm the input.
263( 156)
STEP0.1
_VI3.2
:_
ENT
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com