— 14-2 —
14.1.2. Using TA Command
l “TA” command is to display the alarm code on the Handy Terminal screen.
l In this case, the code is not displayed at different time as the LED display.
◊ Example
◊ Excess position error and heat sink overheat alarms will be displayed as shown in
Figure 14-4.
Figure 14-4: Alarm display
F1>Excess Position Error
P0>Over Heat
:_
F1: Excess position error
P0: Heat Sink Over heat or Regeneration Resistor Over Heat
[Example 1] Identify alarms as the warning lamp of ALARM is on.
1) Confirm that the display of Handy Terminal shows the colon “ : .”
(If the colon “ : “ is not shown in the display, press the ENTER key once.)
:_
2) Input TA command.
:TA_
AT
3) Press ENT key to exeute and the display identifies the alarm.
:TA
F1>Excess Position Error
:_
ENT
l Thus the alarm is identified as “Excess position error”.