— 10-21 —
10.3.2. Analog Velocity Command
l In the velocity control mode operation, the Motor may be controlled directly by inputting analog
command.
◊ Voltage range of analog command is ±10V. The offset adjustment may be performed
with VR1 pod on the front panel of a Driver Unit.
◊ Setting the parameter AC reverses the polarity of analog command voltage.
AC1 : Analog voltage + : CCW
AC -1: Analog voltage + : CW
◊ The parameter AGV changes the relation between analog voltage and velocity.
Table 10-13
DI data AC data
Command
voltage
Rotational
direction
0 1 + CCW
0 1 - CW
0 -1 + CW
0 -1 - CCW
1 1 + CW
1 1 - CCW
1 -1 + CCW
1 -1 - CW
Figure 10-13: Command voltage and velocity
-10V +10V
♦
Resolver resolution: 12 bit
♦
Resolver resolution: 10bit or
automatic switching
CCW Maximum
velocity
CW Maximum
velocity
CCW Maximum
velocity
velocity
velocity
CW Maximum
velocity
AGV = 0.5
AGV = 1.0
Table 10-14 [s
-1
]
Maximum velocity
Motor series
Resolver resolution: 12 bit
Resolver resolution: 10 bit
or automatic switching
YS, JS1, JS2, RS 1 3
SS 1.25 3.75
AS, BS, JS0 1.5 4.5
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com