— 5-12 —
5.2.5. Wiring Example (CN2, CN5)
5.2.5.1. Position Control Mode Wiring Example
Figure 5-12
Polarity of DC24V external power may be
reversed and used as “ minus-common”.
Programmed operation start
Internal program selection bit 5
Internal program selection bit 4
Internal program selection bit 3
Internal program selection bit 2
Internal program selection bit 1
Internal program selection bit 0
Jog operation
Jog direction select
DC24V
Servo-on
Emergency stop
Home limit switch
Integration off
+ direction overtravel limit
- direction overtravel limit
Clear
Home Return start
Position feedback signal øA
Position feedback signal øB
Position feedback signal øZ
DC5V
Driver Unit ready
In-position
Brake control signal
CW pulse train
CCW pulse train
DC24V
Polarity of DC24V external power may be
reversed and used as “minus-common”.
DC24
SVON
EMST
HLS
IOFF
OTP
OTM
CLR
HOS
CWP+
CWP-
CCWP+
CCWP-
DRDY+
DRDY-
IPOS
BRK
COM
CHA
∗
CHA
CHB
∗
CHB
CHZ
∗
CHZ
SGND
DC24
RUN
PRG5
PRG4
PRG3
PRG2
PRG1
PRG0
JOG
DIR
Caution  : • When using an inductive switch (e.g., relay), be sure to insert a serge killer
circuit.
• When the user installs sensors as the Home position limit switch, + direction
overtravel limit and - direction overtravel limit switch, connect sensor output
directly with the input port of the Driver Unit, not via the master controller.
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com