EasyManua.ls Logo

NSK MEGATORQUE M-ESA-Y3040T25 - FW: FIN Width; FZ: Feedback Phase Z Configuration; HA: Home Return Acceleration

Default Icon
294 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
12-16
FW : FIN Width
Format : FW data
Data : 0 or 0.3 ~ 100 [0.1 second]
Shipping set : 1
Default : 0
l Sets the time length of IPOS output. Unit is 0.1 sec.
l If it is set to FW1, the time length of the IPOS output will be 0.1 sec.
l If it is set to FW0, IPOS output is in standard state and always closed when the position error
counter value is less than the “IN” setting.
l When it is set to FW0.3 ~ FW100, IPOS output is closed for the moment as set when the position
error counter value is less than the “IN” value.
l Refer to “9.1.8. In-Position Output” for the output timing.
l “TS” or “?FW” command reports the current setting.
l Set FW0 when the system is performing the pulse train command operation.
« FZ : Feedback Phase Z Configuration
Format : FZ data
Data : 0 or 1
Shipping set : 0
Default : 0
l FZ selects the output format of the position feedback signal CHZ (CN2 output).
FZ0 : Outputs the øZ signal from CHZ.
FZ1 : Outputs MSB of the digital position signal from CHZ.
l Refer to “9.1.9. Position Feedback Signal” for the output timing of the øZ signal or MSB.
l “TS” or “?FZ” command reports the current setting.
HA : Home Return Acceleration
Format : HA data
Data
Motor series
YS, JS1, JS2, RS : 0, 0.01 ~ 80 [s
-2
]
SS : 0, 0.01 ~ 100 [s
-2
]
AS, BS, JS0 : 0, 0.01 ~ 120 [s
-2
]
Shipping set : 1.00 [s
-2
]
Default : Not available
l Sets Home Return acceleration.
l “TS” or “?HA” command reports the current setting.