— 12-35 —
TS : Tell Settings
Format : TS data
Data : 0 ~ 13
Default : 0
l This is to read out parameter settings. The parameter to be read out varries with the data.
1) Standard ESA 25
TS0 : Reads out all parameters listed below.
TS1 : PG, VG, VI, VM, LG, TL
TS2 : FO, FP, FS, NP, NS, DBP, DBA, ILV, FF, FC
TS3 : CO, IN, IS, FW, VO, VW
TS4 : CR, PC, RR
TS5 : FD, FZ, FR
TS6 : PS, DI, OTP, OTM
TS7 : MV, MA, JV, JA, HV, HA, HZ
TS8 : OS, HD, HO
TS9 : PA, OL, RC, LR
TS10: AB, SM, NW
TS11: MM, BM, CM, AN, WM, SE
TS12: LO, SG, MT, RI, ZP, ZV
TS13: SL, AC, AGV, AGT
l Report format may be selected by MM.
VG : Velocity Gain
Format : VG data
Data : 0.1 ~ 255.0 or /AJ (Adjusting mode)
Shipping set : 1.0
Default : Not available
l Sets velocity loop proportional gain.
l “VG/AJ” command starts the fine adjusting program.
l “TS” or “?VG” reports the current setting.
l When LO and SG data are changed, the gain will be automatically adjusted.
l When VG data is changed, LG and SG data will be cleared to 0.