7-1
7. Handy Terminal Communication
l Setting of various parameters, trial running, and adjustment are possible by inputting commands to
the Driver Units through NSK Handy Terminal FHT11. (i.e., communication through the RS-232C
interface).
l The Driver Unit has CN1 as the Input/Output ports for RS-232C communication.
l FHT11 Terminal can be a daisy chain communication terminal. Refer to “9.3.4. Daisy Chain
Communication” for details.
Caution : Always turn off the Driver Unit when plugging on/off the CN1 connector.
Turn off the Driver Unit, if it has been turned on.
Connect FHT11 and the Driver Unit at connector CN1.
The communication will automatically begin when you turn on the control power of the
Driver Unit.
7.1. When Power is Turned on
l If the terminal (NSK Handy Terminal FHT11) is connected to CN1 and the Driver Unit power is
turned on, the message shown below is displayed.
l The contents (and the number of characters) of this message may differ with Driver Unit setting
and system versions.
l When the Driver Units are initialized, a colon ( : ) is displayed and the system waits for a command
to be entered. The colon ( : ) is called a prompt. If the colon ( : ) is not displayed, press ENT key.
Figure 7-1 : Power-On Message
NSK MEGATORQUE
MS1A50_xxxx
Exxxxxxxxxx
:_
Slightly differs with system configurations.
Indicates that internal initialization is completed
and a command may be accepted.