— 12-23 —
MN : Monitor
Format : MN data
Data : 0 ~ 7
Shipping set : 0
Default : 0
l Selects and sets the condition of the analog monitor.
l The setting is not backed-up in the memory. “MN” command must be entered when monitoring is
required.
l Setting can be read by “?MN” command.
l The condition of monitor is shown in the table below.
MN data Monitor output
MN0 Velocity
MN1 Velocity command
MN2 Velocity error
MN3 Torque command
MN4 Phase C current command
MN5 Position command
MN6 Position error (± 127 pulses / ± 10V)
MN7 Position error (± 16 383 pulses / ± 10V)
MO : Motor Off
Format : MO
l When the SVON input (CN2) is ON and the Motor is in the servo-on state, inputting the “MO”
command turns the Motor servo off.
l To activate the Motor servo again, input the “SV” command or the “MS” command.
l When the “MS” command is input, the Motor gets in the servo-on state. This also clears the
inputted operation command previously.
MS : Motor Stop
Format : MS
l When the “MS” command is input during the execution of an operation, the Motor abandons the
programs and stops. At this time, the Motor is in the servo-on state.
l The programs specified before the Motor stop are cleared. If the “MO” command is input to turn
off the Motor servo, inputting the MS command sets the Motor to servo-on again. This also clears
the programs being executed before the input of the “MO” command.
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com