iv
OTP : Overtravel Limit Switch Position------ 12-26
OTM: Overtravel Limit Switch Position -----12-26
PA : Phase Adjust------------------------------ 12-27
PC : Pulse Command-------------------------- 12-27
PG : Position Gain------------------------------ 12-27
PH : Programmed Home Return------------12-28
PS : Position Scale-----------------------------12-28
RA : Read Analog Command----------------12-28
RC : Rated Current (Software Thermal) --12-29
RI : Factory Use Only-------------------------12-29
RR : Resolver Resolution--------------------- 12-29
SE : Serial Error---------------------------------12-29
SG : Servo Gain Adjust, Minor---------------12-30
SI : Set Initial Parameters -------------------12-30
SL : Set Servo Loop---------------------------12-31
SM : Factory use only--------------------------12-31
SP : Start Program -----------------------------12-31
SV : Servo-on------------------------------------ 12-31
TA : Tell Alarm Status-------------------------12-32
TC : Tell Channel Program-------------------12-33
TE : Tell Position Error Counter ------------12-33
TL : Torque Limit Rate------------------------12-33
TP : Tell Position -------------------------------12-34
TR : Tell RDC Position Data-----------------12-34
TS : Tell Settings -------------------------------12-35
VG : Velocity Gain ------------------------------ 12-35
VI : Velocity Integrator Frequency---------12-36
VM : Velocity Integrator Mode --------------- 12-36
VO : Velocity Error Over Limit---------------12-36
VW : Velocity Error Over Limit Width-------12-37
WD : Write Data to EEPROM-----------------12-37
WM : Write Mode to EEPROM----------------12-37
ZP : Factory Use Only-------------------------12-38
ZV : Factory Use Only-------------------------12-38
13. Maintenance----------------------------------13-1
13.1. Precautions ---------------------------------------------13-1
13.2. Maintenance Check ----------------------------------13-2
13.2.1. Motor ----------------------------------------------13-2
13.2.2. Driver Unit and Cable Set--------------------13-2
13.3. Periodical Replacement of Parts ------------------13-3
13.3.1. Motor ----------------------------------------------13-3
13.3.2. Driver Unit----------------------------------------13-3
13.4. Storing ---------------------------------------------------13-3
13.5. Warranty Period and Covering Range-----------13-4
13.5.1. Warranty Period--------------------------------13-4
13.5.2. Range of Warranty-----------------------------13-4
13.5.3. Immunities ---------------------------------------13-4
13.5.4. Service Fee--------------------------------------13-4
14. Alarm--------------------------------------------14-1
14.1. Identifying Alarm---------------------------------------14-1
14.1.1. LED Alarm Indicator---------------------------14-1
14.1.2. Using TA Command---------------------------14-2
14.1.3. Alarm Code List---------------------------------14-3
14.2. Description of Alarm ----------------------------------14-4
14.2.1. Normal State ------------------------------------14-4
14.2.2. Alarms Related to Power Amplifier--------14-4
14.2.2.1. Heat Sink Overheat or
Regeneration Resistor Overheat------14-4
14.2.2.2. Abnormal Main AC Line Voltage----14-5
14.2.2.3. Over Current------------------------------14-5
14.2.2.4. Control AC Line Under-Voltage-----14-6
14.2.3. Alarms Related to Motor----------------------14-7
14.2.3.1. Resolver Circuit Error------------------14-7
14.2.3.2. Software Thermal Sensor-------------14-7
14.2.3.3. Velocity Error Over----------------------14-8
14.2.4. Alarms Related to Control--------------------14-9
14.2.4.1. Memory Error-----------------------------14-9
14.2.4.2. EEPROM Error---------------------------14-9
14.2.4.3. System Error-----------------------------14-9
14.2.4.4. CPU Error-------------------------------14-10
14.2.4.5. Interface Error--------------------------14-10
14.2.4.6. Analog Command Error-------------14-10
14.2.4.7. Excess Position Error----------------14-11
14.2.4.8. Software Over Travel Limit---------14-11
14.2.4.9. Hardware Over Travel Limit--------14-12
14.2.4.10. Emergency Stop---------------------14-12
14.2.4.11. Program Error------------------------14-12
14.2.4.12. Automatic Tuning Error------------14-13
14.2.4.13. RS-232C Error-----------------------14-13
14.2.4.14. CPU Error-----------------------------14-14
14.2.5. History of Alarm-------------------------------14-15
14.2.5.1. Indication of History of Alarm ------14-15
14.2.5.2. Clear History of Alarm ---------------14-15
15. Troubleshooting -----------------------------15-1
15.1. Identifying Problem -----------------------------------15-1
15.2. Troubleshooting----------------------------------------15-2
15.2.1. Power Trouble ----------------------------------15-3
15.2.2. Motor Trouble -----------------------------------15-4
15.2.3. Command Trouble -----------------------------15-6
15.2.4. Terminal Trouble-----------------------------15-10
Appendix
Appendix 1: Verify Input / Output Signal----------------- A-1
Appendix 2 : How to Check Motor Condition ----------- A-5
Appendix 3 : Initializing Driver Unit------------------------ A-9
Appendix 4 : How to Replace ESA25 Driver Unit-----A-11
Appendix 5 : Regeneration Dump Resistor ------------A-18
Appendix 6: Brake Built in YS Series Motor------------A-19
Appendix 7: Parameter • Program Setting List--------A-23
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com